• 6 Core Fiber Optic Network Cable 62.5/125 Low Smoke Blue.
  • ACOLAN®  Loose Tube
  • 6 fibers – Indoor/Outdoor – LSOH
  • Dielectric – Dry water tightness
  • 62.5/125 OM1

The ACOLAN optical offer addresses all the requirements of network construction in professional buildings and for interconnections between the buildings and outside services (security and safety, access control, surveillance…)

The ACOLAN optical offer also covers every building sector: tertiary, industrial centers, logistical centers, train stations, ports, airports, shopping malls, hospitals, university and education, sport & leisure, museums. 

Advantages

  • ACOME's range of LAN and optical cables is designed on the basis of the company's know how in the manufacturing of fiber, designing cables, and in total awareness of the implementation and control problem issues.
  • The range is wide, covering every cable application for cords, up to high-capacity cables for indoor installations.

Features

ACOME proposes several cable ranges adapted to various needs:

  • Compact-tube" structure cables for outdoor cabling
  •  Versions designed for pulling through conduits
  • Central Loose Tube and Loose Tube cables assembled for Interconnection of buildings and optical communication lines
  • Standard indoor/outdoor versions, reinforced, with steel reinforcement
  • Mini Break-out (900µm fiber) for spurs or capillary wiring
  • Standard or reinforced versions
  • Cables for cords

The current fiber standards will allow transmissions over the following lengths:

Max. distance

OM1

OM2

OM3

OM4

OS2

Fast Ethernet

2,000m

2,000m

2,000m

2,000m

10,000m

Giga Ethernet

275m

550m

1,000m

1,100m

10,000m

10 Giga

33m

82m

300m

550m

10,000m

40-100Giga

100m

150m

10,000m

ACOME proposes a range of fibers addressing the market

Write a review

Note: HTML is not translated!
Captcha

6 Core Fiber Optic Network Cable 62.5/125 Low Smoke Blue.

  • AED5.25

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

Cabinet with tambour doors 2 FH (D 430).

Cabinet with tambour doors 2 FH (D 430).

Specification:Completely bonded and doweled corpus made of melamin resin coated chipboards accordin..

Replacement module for BDG-012-V/1-xRx

Replacement module for BDG-012-V/1-xRx

SPD - for data, signalling and telecommunications lines / I&C / Spare modules.Replacement module..

Tool Kit Field Engineer's Double Sided Gray Condura Case

Tool Kit Field Engineer's Double Sided Gray Condura Case

SpecificationsDimensions (ID) (L x W x D):16-1/4 x 12 x 4-1/2"Dimensions (L x W x D):16-1/4' x 12" x..

Lightning current arrester for 3-phase TN-S system, 100 kA (10/350 µs)

Lightning current arrester for 3-phase TN-S system, 100 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Four-pole high ..