• Heavy-Duty 2 Core Control Cable 2.5mm² PVC Sheathed 305m.

Applications

These PVC cables are used in industrial applications for signal transmission. They can be easily used with their

flexible construction in narrow applications like: electronic control systems of computer or audio systems

or in communication sector, electronic circuits, measurement devices, machine design, office equipment, etc.

They are for indoor applications.


Construction

 

Conductor

Stranded Electrolytic Annealed Copper  (IEC /EN 228 / VDE0295 / HD383 / BS 6360  Class 5, 0.34 mm² : Column 2)

Insulation

PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2),  Color Code : DIN 47100

Lay-up

Cores stranded in layers

Outer Sheath

PVC  (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM1)  Outer Sheath Color : RAL 7001 Grey

Reference Standards

VDE 0812

Flame Test

IEC / EN  60332-1, VDE 0482-265-2-1


Technical and Electrical Properties (20°C)


Operating Voltage

0.14 mm²...0.25 mm²

250 V

0.34 mm²...1.50 mm²

300 V / 500 V

2.50 mm².................

450 V / 750 V

Test Voltage

0.14 mm²...0.25 mm²

1200 V

0.34 mm²...1.00 mm²

1500 V

1.50 mm²................

2500 V

Insulation Resistance

Min. 200 M.Ohm x Km

 

Inductance

Approx.    0.65 mH / Km

Current Carrying Capacity

See Technical Data Table 4

Temperature Range

Fixed

-30°C... + 70°C

Flexible

-5°C... + 70°C

Minimum Bending Radius

Fixed

7.5 x Cable Diameter

Flexible

15 x Cable Diameter


Cross Section

Conductor Resistance
(Max. Ω/Km)

Capacitance
(Core/Core nF/Km)

0.14 mm²

138.0

80

0.22 mm²

85.0

100

0.25 mm²

77.8

100

0.34 mm²

56.0

100

0.50 mm²

39.0

110

0.75 mm²

26.0

110

1.00 mm²

19.5

120

1.50 mm²

13.3

120

2.50 mm²

7.98

14

 *  4.00 mm²  6.00 mm²  and also LSF type of LIYY cables can be produced as well.

*  LIYY-OZ: black cores  with numbers ;  LIYY-JZ: black cores with numbers + one green/yellow core


Write a review

Note: HTML is not translated!
Captcha

Heavy-Duty 2 Core Control Cable 2.5mm² PVC Sheathed 305m.

0 reviews / Write a review

  • AED3.70

* Required fields



Related Product

PRO2™ Switched POPS STV-6501 20-30A/16-32A 208V/230V 3-Ph (24) C13 &(6) C19

PRO2™ Switched POPS STV-6501 20-30A/16-32A 208V/230V 3-Ph (24) C13 &(6) C19

The Server Technology® PRO2 Switched POPS CDU provides control of outlet power and local LED input c..

AED11,180.00

Galvanised cable and rope protecting device
Desk with right office pedestal (W1710,H720, D870) CRS.

Desk with right office pedestal (W1710,H720, D870) CRS.

Basic desk: With lockable office pedestal, right.Drawer height, 3 x 150 mm.With 1 utility extensi..

Knürr Elicon® VC Rear Panels Leg area- straight (W- 2000, H- 300).

Knürr Elicon® VC Rear Panels Leg area- straight (W- 2000, H- 300).

Material / Finish: Steel panel, powder-coated.Color: RAL9006 White aluminium.Supply schedu..