Applications
These shielded and PVC insulated cables are used as signal transmission cables in industrial applications.
They can be easily used with their flexible construction in narrow applications like: electronic control systems
of computer or audio systems or in communication sector, electronic circuits, measurement devices, machine
design, office equipment, etc. They are used for indoor applications. Screening protects the cable from the outer electrical effects.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Separator | Polyester tape |
Drain Wire | Stranded Tinned Copper |
Shielding | AL-PES tape |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM 1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1 , VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross | Conductor Resistance | Capacitance | Capacitance |
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 180 |
* 2.50 mm² - 4.00 mm² 6.00 mm² and also LSF type of LIY(St)Y cables can be produced as well.
* LIY(St)Y-OZ : black cores with numbers ; LIY(St)Y-JZ : black cores with numbers + one green/yellow core
Industrial Control Signal Cable 4 Core 1.5mm² Shielded.
Related Product
U Clamps for Cable Management, Range 34-40mm (25pc/pkt)
For strain relief and individual routing of cables and lines – Clamping range, 8-64 mmMaterial..
Knürr Dacobas® 19” Cabinet Type B, Width 600 mm Without front door, D 870 mm. ( Stationary).
Specification:With fixed 19“ mounting on the front and rear for DIN EN 60297-3 compliant component..
2C Unshielded 16AWG Strand (19x29), PVC Grey 305m/Roll.
Webb signal/control cables are multi-conductor cables used in automation and instrumentation appli..
Stackable shelf unit 3 FH (D430).
Specification:Completely bonded and doweled corpus made of melamin resin coated chipboards accordin..