Applications
These shielded and PVC insulated cables are used as signal transmission cables in industrial applications.
They can be easily used with their flexible construction in narrow applications like: electronic control systems
of computer or audio systems or in communication sector, electronic circuits, measurement devices, machine
design, office equipment, etc. They are used for indoor applications. Screening protects the cable from the outer electrical effects.
Construction
Conductor | Stranded Electrolytic Annealed Copper (IEC /EN 228 / VDE0295 / HD383 / BS 6360 Class 5, 0.34 mm² : Column 2) |
Insulation | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281-TI2), Color Code : DIN 47100 |
Lay-up | Cores stranded in layers |
Separator | Polyester tape |
Drain Wire | Stranded Tinned Copper |
Shielding | AL-PES tape |
Outer Sheath | PVC (EN 50290-2 / HD 21.1.S4 / VDE 0281 TM 1) Outer Sheath Color : RAL 7001 Grey |
Reference Standards | VDE 0812 |
Flame Test | IEC / EN 60332-1 , VDE 0482-265-2-1 |
Technical and Electrical Properties (20°C)
Operating Voltage | 0.14 mm²...0.25 mm² | 250 V |
0.34 mm²...1.50 mm² | 300 V / 500 V | |
2.50 mm²................. | 450 V / 750 V | |
Test Voltage | 0.14 mm²...0.25 mm² | 1200 V |
0.34 mm²...1.00 mm² | 1500 V | |
1.50 mm²................ | 2500 V | |
Insulation Resistance | Min. 200 M.Ohm x Km | |
Inductance | Approx. 0.65 mH / Km | |
Current Carrying Capacity | See Technical Data Table 4 | |
Temperature Range | Fixed | -30°C... + 70°C |
Flexible | -5°C... + 70°C | |
Minimum Bending Radius | Fixed | 7.5 x Cable Diameter |
Flexible | 15 x Cable Diameter |
Cross | Conductor Resistance | Capacitance | Capacitance |
0.14 mm² | 138.0 | 80 | 120 |
0.22 mm² | 85.0 | 100 | 150 |
0.25 mm² | 77.8 | 100 | 150 |
0.34 mm² | 56.0 | 100 | 150 |
0.50 mm² | 39.0 | 110 | 170 |
0.75 mm² | 26.0 | 110 | 170 |
1.00 mm² | 19.5 | 120 | 180 |
1.50 mm² | 13.3 | 120 | 180 |
* 2.50 mm² - 4.00 mm² 6.00 mm² and also LSF type of LIY(St)Y cables can be produced as well.
* LIY(St)Y-OZ : black cores with numbers ; LIY(St)Y-JZ : black cores with numbers + one green/yellow core
305m Shielded Control Signal Cable 4 Core 18 AWG Wiring.
Related Product
Manual shear for wires and cable
SpecificationPart Number<-->kgJVM-FC090325mm0,8JVM-FC120500mm1,5JVM-FC160630mm2,3JVM-FC160E630..
Knürr Elicon® VideoWall Perforated sheet panel W2000 H550.
Specification:For installation below the monitors on the front side or as a complete cladding on t..
KVM 4-port PS/2-USB Audio Enabled. Multi-Platform
CS1754 is a KVM Switch with 4 ports and supports computers with PS/2 or USB interfaces via cables an..
2m UK Plug To IEC C19 Power Cable 13A For Servers And UPS.
Interconnecting Power leads & links2 Metre male to female IEC16 Amp IEC 60320Fused @ 13Amps..
AED90.00