• Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

Areas of Use

These shielded and Halogen Free Flame Retardant insulated cables are used as signal transmission cables in industrial applications. These can be easily used with their flexible construction in narrow applications like electronic control systems of computer or audio systems or in the communication sector, electronic circuits, measurement devices, machine design, office equipment, etc. These used for indoor applications. Screening protects the cable from the outer electrical effects. Because of the HFFR material, These don't burn easily and if these do, flames go off by themselves. These have low smoke density and these don't emit poisonous and corrosive gases during the fire. These used in buildings where there are important goods or the human population.

Cable Construction

 

Conductor

Stranded Annealed Copper (IEC/EN 60228, Class 5, 0.34 mm²: Class 2)

Insulation

HFFR (EN 50290-2-26)

Core Colors

DIN 47100 (4 cores colors, white, yellow, brown, green)

Lay-up

Cores are stranded in layers

Separator

PET Foil

Drain Wire

Stranded Tinned Copper

Screen

Al-PET Foil

Outer Sheath - Grey

HFFR (EN 50290-2-27), RAL 7001

Reference Standards

VDE 0812, TS 13755

 

Technical Properties

Operating Voltage

0.14 mm²..0.25 mm² 250 V; 0.34 mm²..1.50 mm² 300 V / 500 V; 2.50 mm²…... 450 V / 750 V

Test Voltage

0.14 mm² - 800 V; 0.22 mm² ….1.00 mm²- 1200 V; 1.50 mm²….. 2.50 mm² - 2500 V

Conductor Resistance

0.14 mm²- ≤138 Ω/km; 0.22 mm²- ≤85 Ω/km; 0.25 mm²- ≤77.8 Ω/km; 0.34 mm²- ≤56 Ω/km; 0.50 mm²- ≤39 Ω/km; 0.75 mm²- ≤26Ω/km; 1.00 mm²- ≤19.5 Ω/km; 1.50 mm²- ≤13.3 Ω/km; 2.50 mm²- ≤7.98 Ω/km

Insulation Resistance

>200 M.Ωxkm

Capacitance (@800Hz)

Core - Core: 0.14 mm²-≤80 nF/km; 0.22 mm²..0.34 mm²-≤100 nF/km; 0.50 mm²..0.75 mm²-≤110 nF/km; 1.00 mm²..1.50 mm²-≤120nF/km; 2.50 mm²- ≤140 nF/km Core-Screen: 0.14 mm²-≤120 nF/km; 0.22 mm²..0.34 mm²-≤150 nF/km; 0.50 mm²..0.75 mm²-≤170 nF/km; 1.00 mm²..1.50 mm²-≤180nF/km; 2.50 mm²- ≤240 nF/km

Indutance (approx.)

0.65 mH/km

Temperature Range

Fixed: -30 °C ........+70 °C, Flexible: -5 °C ........+70 °C

Flame Retardancy

IEC/EN 60332-1

Smoke Density

IEC/EN 61034-2

Amount of Halogen Acid Gas

IEC/EN 60754-1

Corrosive Gases Measurement

IEC/EN 60754-2

Min. Bending Radius

Fixed: 8 x Cable Diameter, Flexible: 15 x Cable Diameter

 

Write a review

Note: HTML is not translated!
Captcha

Cable Control 2C 1Sqmm LIH(st)H/18AWG SCN- 100m/Roll

0 reviews / Write a review

  • AED 2.60

* Required fields



Related Product

Adjustable boom with cable guiding device

Adjustable boom with cable guiding device

Specification<-->kg140-240cm17..

ERGOCON WorkStation _ Control Room Console _ KVM-ready Technology Cabinet _ W2400 D1100 _ Rectangular

ERGOCON WorkStation _ Control Room Console _ KVM-ready Technology Cabinet _ W2400 D1100 _ Rectangular

KVM-ready Technology Cabinet :- Upto 3x6 RU for integrating technology, typical for KVMapplicat..

Levelling Feet For Free Standing M12 - 4/Set

Levelling Feet For Free Standing M12 - 4/Set

Levelling Feet For Free Standing M12 - 4/Set..

Surge arrester ,TN and TT systems, up to 150 V AC, 40 kA (8/20 µs)

Surge arrester ,TN and TT systems, up to 150 V AC, 40 kA (8/20 µs)

Pluggable module, visual fault signalling.Varistor surge arrester.Installation to LV installations, ..