Fine protection for one port of Ethernet Cat. 5e. installation at the boundary of LPZ 2 and LPZ 3 zones directly in front of the device.
Technical specifications
Type of SPD | C2,C3 | |
Location of SPD | ST 3 | |
Maximum operating voltage | Uc | 6V DC and 9V DC |
Nominal load current | IL | 0,500A |
C2 nominal discharge current (8/20 µs) per core | In | 0,20kA |
C2 total discharge current (8/20 µs) cores-PE | ITotal | 1,60kA |
C2 voltage protection level mode core-core at In | Up | 40V |
C2 voltage protection level mode core-PE at In | Up | 350V |
C3 voltage protection level mode core-core at 1 kV/µs | Up | 65V |
C3 voltage protection level mode core-PE at 1 kV/µs | Up | 350V |
Response time core-core | ta | 1ns |
Response time core-core | ta | 100ns |
Insertion attenuation at 250 MHz | 1,20dB | |
Connection (input - output) | RJ 45/RJ 45 | |
Degree of protection | IP 20 | |
Range of operating temperatures - min | -40 °C | |
Range of operating temperatures - max | 80 °C | |
According to standard | EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012 | |
ETIM Class | EC000943 |
DL-Cat. 5e
Related Product
Portable Equipment Trolley With Integrated Storage Drawers.
Replace „x“ with the number of your color choice.Final digit of order number .1:Worktops, RAL 7035, ..
Shelf Chasis Tray 2U 432X280 - RAL7035
For installation in racks with fixed 19” installation on the frontQuick and easy mounting on 19” ext..
SX-090 F75 F/F
BNC or F connectorsFine protection for coaxial inputs of TV systems. Suitable as the 2nd level of su..
Lightning current arrester for 3-phase TT system, 100 kA (10/350 µs)
Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of ..