Fine protection for one port of Ethernet Cat. 5e. installation at the boundary of LPZ 2 and LPZ 3 zones directly in front of the device.
Technical specifications
Type of SPD | C2,C3 | |
Location of SPD | ST 3 | |
Maximum operating voltage | Uc | 6V DC and 9V DC |
Nominal load current | IL | 0,500A |
C2 nominal discharge current (8/20 µs) per core | In | 0,20kA |
C2 total discharge current (8/20 µs) cores-PE | ITotal | 1,60kA |
C2 voltage protection level mode core-core at In | Up | 40V |
C2 voltage protection level mode core-PE at In | Up | 350V |
C3 voltage protection level mode core-core at 1 kV/µs | Up | 65V |
C3 voltage protection level mode core-PE at 1 kV/µs | Up | 350V |
Response time core-core | ta | 1ns |
Response time core-core | ta | 100ns |
Insertion attenuation at 250 MHz | 1,20dB | |
Connection (input - output) | RJ 45/RJ 45 | |
Degree of protection | IP 20 | |
Range of operating temperatures - min | -40 °C | |
Range of operating temperatures - max | 80 °C | |
According to standard | EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012 | |
ETIM Class | EC000943 |
DL-Cat. 5e
Related Product
Arrestor 3 Pole T-83 A230XF4
Overvoltage arrester 3-pole, Dia-8x13 230 V, 10 kA / 10A with fail safe..
AED 3.83
Lightning current arrester replacement module, of two 2-core signalling lines, 6 V DC, max. 1 A
Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..
Patch Cord Booted CAT5E 3m - Grey- Fusion
High quality Cat 5e UTP Patch Lead Wired 258A (T568B) 50 Micron Gold Plated RJ45 connectors.Each lea..
AED 6.27
CABLE DRUM TRESTLE, HYDRAULIC, 3000Kg Capacity
Hydraulic Cable Drum Trestle or Cable Drum Jack with Foot PumpSpecificationUsed to support cable&nbs..
AED 3,591.00