• DM-PROFIBUS 5 V

Protection of line and communication interfaces of the PROFIBUS industrial bus-bar system. Coarse and fine surge protection. Also, cable shielding is protected.

Parameters

Type of SPD

 

C2,C3

Connection (input - output) 

 

terminals-terminals

Location of SPD 

 

ST 2+3

Nominal voltage 

Un

5V DC

Maximum operating voltage

Uc

6V AC

Maximum operating voltage

Uc

8V AC

Nominal load current

IL

0,060 A

C2 nominal discharge current (8/20 µs) core-core 

In

10,00Ka

C2 voltage protection level mode core-core at In 

Up

150 V

C2 voltage protection level mode core-COM at In 

Up

150 V

C2 voltage protection level mode COM-PE at In 

Up

350 V

C2 voltage protection level mode SH-PE at In 

Up

350 V

C3 voltage protection level mode core-core at 1 kV/µ

Up

40 V

C3 voltage protection level mode core-COM at 1 kV/µs

Up

40 V

C3 voltage protection level mode COM-PE at 1 kV/µs

Up

650 V

C3 voltage protection level mode SH-PE at 1 kV/µs

Up

650 V

Response time core-core 

ta

1 ns

Response time core COM

 

1 ns

Response time COM-PE

ta

100ns

Response time SH-PE 

ta

100ns

Serial resistance per core 

R

1,00Ω

Treshold frequency core-core

f

100,00MHz

Cross-section of connected conductors solid - max 

 

400 mm2

Cross-section of connected conductors stranded - max 

 

2,50 mm2

Degree of protection

 

Write a review

Note: HTML is not translated!
Captcha

DM-PROFIBUS 5 V

* Required fields


Terms & Conditions

All prices are subject to confirmation and exclude applicable taxes unless otherwise stated. Payment terms are as agreed in the quotation or invoice. Orders will be processed only after payment confirmation or receipt of an approved purchase order, where applicable. Dafnia reserves the right to modify product pricing, availability, and payment terms without prior notice.


Related Product

ESD Safe Electronics Workstation Desk With 3-Drawer Right Pedestal(W1140,H750).

ESD Safe Electronics Workstation Desk With 3-Drawer Right Pedestal(W1140,H750).

Specifications: Combi desk with 4 legs and link-up extrusion. Offset leg to ensure u..

Combination of lightning ,TT, 100 kA (10/350 µs), 100 kA (8/20 µs)

Combination of lightning ,TT, 100 kA (10/350 µs), 100 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking.Combination of three-pole high performance..

STICKLERS™ ENTERPRISE FIELD INSPECTION FIBER OPTIC CLEANING KIT

STICKLERS™ ENTERPRISE FIELD INSPECTION FIBER OPTIC CLEANING KIT

Product Features:Inspect, Clean, Inspect – less than ten seconds to complete to ensure you get the j..

Heavy Duty 36U Server Rack Side Shield - Outer Enclosure Wall

Heavy Duty 36U Server Rack Side Shield - Outer Enclosure Wall

19“ Technology Side Panel HU36 D HU Order no. UP ..