BNC or F connectors
Type of SPD | | D1,C2,C3 |
Location of SPD | | ST 2+3 |
Maximum operating voltage | Uc | 29 V DC |
Nominal load current | IL | 4,000 A |
C2 nominal discharge current (8/20 µs) core-PE | In | 1,50kA |
C3 voltage protection level mode core-PE at 1 kV/µs | Up | 80V |
Wave impedance | Z | 75Ω |
Insertion attenuation | | 1,00 dB |
SWR | | 1,7 |
Bandwidth - min | f | 1,00MHz |
Bandwidth - max | f | 2150,00 MHz |
Connection (input - output) | | BNC 50 |
Degree of protection | | IP 20 |
Range of operating temperatures - min | | -40 °C |
Range of operating temperatures - max | | -80 °C |
Mounting | | DIN rail 35 mm |
According to standard | | EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012 |
ETIM Class | | EC001466 |
SX-090 F75 F/F
Related Product
Basic Frames for circular cover panels, straight (D- D1050).
Specification:Basic frames for straight or lowered worktops, for depths of 1050 or 1200mm, in versi..
Surge protection for two 1-core signalling networks, terminal block with screw terminals, 60 V DC, max. 0.5 A
Coupling impedance (resistance), screw terminals.Coarse and fine surge protection for two 1-core sig..
Open Frame Base 19" D600 RAL7035
Open Frame Base 19" D600 RAL7035...
VOLTASIX • ø 6 mm - Accessories and spare parts
Starting/Ending ends with M6 threadSpecificationPart Numberø mmgrGVSR813..