•  DP-060-V/1-F16

Protection of power supply with output from the midle and non-grounded pole, also for powwer suply with

one pole grounded. Installation as close as possible to the protected equipment.

Technical specifications

Type of SPD

 

T3, C2

Connection (input - output) 

 

terminals-terminals

Location of SPD 

 

ST 2

Nominal voltage

Un

60V AC

Maximum operating voltage 

Uc

75V AC and 75V DC

Nominal load current 

IL

16,000A

C2 nominal discharge current (8/20 µs) per core 

In

2,00kA

C2 voltage protection level mode core-core at In

Up

390V

C2 voltage protection level mode core-PE at In 

Up

750,00V

Test voltage L+ - L- 

 

4,0kV

Test voltage L+(L-)-PE 

 

4,0kV

Test voltage M-PE 

 

4,0kV

voltage protection level L+ - L- 

 

0,39 kV

voltage protection level L+(L-)-PE

 

0,75 kV

voltage protection level M-PE 

 

0,75 kV

Maximum overcurrent protection 

 

16 A gL/gG or B 16 A

Response time L+ - L-

 

25ns

Response time L+(L-)-PE 

 

100ns

Response time M-PE 

 

100ns

Cross-section of connected conductors solid (min) 

 

0,14mm2

 

Cross-section of connected conductors solid (max) 

 

4,00 mm2

Cross-section of connected conductors stranded (min) 

 

0,14 mm2

Cross-section of connected conductors stranded (max)

 

2,50 mm2

Fault indication

 

red indicator

Degree of protection 

 

IP 20

Range of operating temperatures - min

 

-40 °C

Range of operating temperatures - max 

 

-70 °C

Mounting 

 

DIN rail 35 mm


Write a review

Note: HTML is not translated!
Captcha

DP-060-V/1-F16

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Cabinet Server 27U W800D1000 W/4Fan+cast+SP W/o Door-9005.

Cabinet Server 27U W800D1000 W/4Fan+cast+SP W/o Door-9005.

Server cabinets are designed to store and safeguard the primary active components in a data networ..

Horizontal T 360x100mm.

Horizontal T 360x100mm.

Features:- Horizontal T is used to establish a 3-way right-angled intersection and three joiners ar..

Straight Cable Roller, Galv. Reinforced HD Wt. 5,5Kg.

Straight Cable Roller, Galv. Reinforced HD Wt. 5,5Kg.

Cable laying ground roller fit for installations,cables with ø 190 mm max.Composed by: - tubular f..