•  FX-090 B75 T F/F
BNC connectors
Protection for coaxial lines. Installation at the boundary of LPZ 0 and LPZ 1 zones at the line input into the
building. Suitable as the 1st level of surge protection in coordination with the SX type.

Parameters

 

Type of SPD 

 

D1,C2

Location of SPD 

 

ST 1

Maximum operating voltage

Uc

70 V DC

Nominal load current 

IL

4,000 A

C2 nominal discharge current (8/20 µs) core-SH 

In

10,00KA

C2 nominal discharge current (8/20 µs) SH-PE 

In

10,00KA

D1 impulse discharge current (10/350 µs) core-SH 

Iimp

2,50kA

D1 impulse discharge current (10/350 µs) core-PE

Iimp

2,50kA

C3 voltage protection level mode core-SH at 1 kV/µs

Up

600v

C3 voltage protection level mode SH-PE at 1 kV/µs 

Up

600v

Wave impedance 

Z

75Ω

Insertion attenuation 

 

0,60 dB

SWR 

 

1,2

Bandwidth - min

f

0,00MHZ

Bandwidth - max 

f

2150,00MHz

Response time core-SH 

ta

100ns

Response time SH-PE 

ta

100ns

Connection (input - output) 

 

BNC 75

Degree of protection

 

IP 20

Range of operating temperatures - min

 

-40 °C

Range of operating temperatures - max 

 

-80 °C

Mounting

 

DIN rail 35 mm

According to standard 

 

EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012

ETIM Class 

 

EC001466

Write a review

Note: HTML is not translated!
Captcha

FX-090 B75 T F/F

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Fan 2Way With UK Plug And Cord Length 2m - RAL9005

Fan 2Way With UK Plug And Cord Length 2m - RAL9005

Fan Assembly Top Cover Mount2 Fans with 2 Metre Cord and UK 3 Pin Plug..

AED164.02

HE-XX series Patchcords

HE-XX series Patchcords

Product details:The OPTOKON introducing new effective low cost harsh environment connectors HE-XX s..

Lightning current arrester replacement module for 2/3-core signalling lines, 24 V DC, max. 2 A

Lightning current arrester replacement module for 2/3-core signalling lines, 24 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Surge protection for 2-core signalling lines, installation close to protected equipment, 12 V DC, max. 2 A

Surge protection for 2-core signalling lines, installation close to protected equipment, 12 V DC, max. 2 A

Coupling impedance (L2 – inductance).Coarse and fine surge protection for 2-core signalling lines.In..