Pluggable module, visual fault signalling,
middle conductor separated from protective earth via GDT.
- Surge protection for all types of LV electric
and electronic equipments against surge voltage.
- Installation to LV installations, close to
protected equipment.
- For protection of the equipments against impact of induced overvoltages during a lightning strike or switching overvoltages.
Specifications:
Parameter name |
Parameter value |
|
Type
of SPD |
T3, C2 |
|
Location
of SPD |
ST 2 |
|
Mounting |
DIN rail 35 mm |
|
Nominal
voltage |
Un |
48 V AC |
Maximum
operating voltage |
Uc |
60.00 V AC |
Maximum
operating voltage |
Uc |
60.00 V DC |
Nominal
load current |
IL |
16.000 A |
Maximum
overcurrent protection |
16 A gL/gG or B 16 A |
|
C2
nominal discharge current (8/20 µs) per core |
In |
2.00 kA |
Test
voltage L+ - L- |
4.0 kV |
|
Test
voltage L+(L-)-PE |
4.0 kV |
|
Test
voltage M-PE |
4.0 kV |
|
voltage
protection level L+ - L- |
0.37 kV |
|
voltage
protection level L+(L-)-PE |
0.75 kV |
|
voltage
protection level M-PE |
0.75 kV |
|
C2
voltage protection level mode core-PE at In |
750.00 V |
|
C2
voltage protection level mode core-PE at In |
Up |
750 V |
C2
voltage protection level mode core-core at In |
Up |
370 V |
Response
time L+ - L- |
25 ns |
|
Response
time L+(L-)-PE |
100 ns |
|
Response
time M-PE |
100 ns |
|
Connection
(input - output) |
terminals-terminals |
|
Cross-section
of connected conductors solid (min) |
0.14 mm2 |
|
Cross-section
of connected conductors solid (max) |
4.00 mm2 |
|
Cross-section
of connected conductors stranded (min) |
0.14 mm2 |
|
Cross-section
of connected conductors stranded (max) |
2.50 mm2 |
|
Fault
indication |
red indicator |
|
Degree
of protection |
IP 20 |
|
Range
of ambient temperatures (min/max) |
-40 / 70 °C |
|
Humidity |
5 - 95 % |
|
According
to standard |
EN 61643-21+A1,A2:2013, IEC
61643-21+A1,A2:2012, EN 61643-11:2012, IEC 61643-11:2011 |
|
ETIM
Class |
EC000942 |
|
Plug
module |
DP-048-V/1-0 |
|
Customs
tariff number |
85363030 |
|
EAN |
8595090556664 |
Dimensions:
Replacement module: DP-048-V/1-0
Surge protection for small-voltage AC/DC power supply networks, up to 48 V DC, pluggable module
Related Product
Two-stage surge protection, LPZ0 and higher
RJ45 sockets.Combination of coarse and fine protection of Ethernet line with PoE.Instalation at th..
Two-stage surge protection, LPZ0 and higher
RJ45 sockets.Combination of coarse and fine protection of Ethernet line with PoE.Instalation at th..
Two-stage surge protection for outdoor Ethernet devices with PoE
Surge protection for outdoor Ethernet devices with PoE.Two-stage Ethernet surge protection in comb..
Surge protection for ISDN telecommunication line, RJ45 sockets
RJ45 socketsCombination of coarse and fine protection for ISDN lines.For protection of one pair o..