LPZ 1 and higher, Ethernet without PoE
- Fine surge protection.
- Installation at protected device inside LPZ1 and higher (not suitable for LPZ 0).
- For pprotection of Ethernet networks (up to Cat.6A) without PoE.
- Installation into DL-PL-RACK-1U box.
- DL-...-M with front output.
- DL-...-R-M with rear output.
- Not applicable for Ethernet with PoE.
Specifications:
Parameter
name |
Parameter value |
|
Type of SPD |
C2,C3 |
|
Location of SPD |
ST 2+3 |
|
Mounting |
DL-PL-RACK-1U |
|
Maximum operating
voltage |
Uc |
6.00 V AC |
Maximum operating
voltage |
Uc |
8.50 V DC |
Maximum operating
voltage POE |
Uc |
6.00 V AC |
Maximum operating
voltage POE |
Uc |
8.50 V DC |
Nominal load current
per core at 25 °C |
IL |
0.5 A |
Treshold frequency core-core |
f |
500.00 MHz |
Insertion attenuation
at treshhold frequency |
2.90 dB |
|
C2 nominal discharge
current (8/20 µs) per core |
In |
0.20 kA |
C2 total discharge
current (8/20 µs) cores-PE |
ITotal |
1.60 kA |
C2 voltage protection
level mode (POE) at In |
Up |
55.00 V |
C2 voltage protection
level mode core-PE at In |
Up |
400 V |
C2 voltage protection
level mode core-core at In |
Up |
55 V |
C3 voltage protection
level mode (POE) at 1 kV/µs |
30.00 V |
|
C3 voltage protection
level mode core-PE at 1 kV/µs |
Up |
600 V |
C3 voltage protection
level mode core-core at 1 kV/µs |
Up |
30 V |
Response time
core-core |
ta |
1 ns |
Response time core-PE |
ta |
100 ns |
Connection (input -
output) |
RJ 45/RJ 45 |
|
Degree of protection |
IP 20 |
|
Range of ambient
temperatures (min/max) |
-40 / 80 °C |
|
Humidity |
5 - 95 % |
|
According to standard |
EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012 |
|
Customs tariff number |
85363010 |
|
EAN |
8595090541967 |
Dimensions:
SPD for high-speed Ethernet networks, LPZ 1 and higher
Related Product
Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)
Spark gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 3+1 mode.Installa..
Lightning current arrester between N and PE , TT system, 50 kA (10/350 µs)
park gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 1+1 mode.Installat..
Lightning current and surge arrester ,TT, 50 kA (10/350 µs), 100 kA (8/20 µs)
Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of v..
Lightning current and surge arrester , TT, 50 kA (10/350 µs), 100 kA (8/20 µs)
Pluggable module, visual fault signalling, module locking.Combination of varistor lightning current ..