Pluggable module, visual fault signalling, module locking, onto 40 mm busbar system.
- High performance lightning current arrester, installation at the boundary of zones LPZ 0 and LPZ 1 or higher, mainly to main distribution boards upstream power meters.
- For protection against impact of direct or indirect lightning strikes in wide range of applications – houses, office or industrial buildings, resp. to sub- distribution boards in large buildings, for application in Germany.
Specifications:
Parameter name |
Parameter
value |
|
Type of SPD |
T1,T2,T3 |
|
Mounting |
40
mm busbar system |
|
Nominal voltage |
Un |
230
V AC |
Maximum operating voltage |
Uc |
255.00
V AC |
Type of network |
TN |
|
Maximum overcurrent protection |
160
A gL/gG |
|
Short-circuit current rating |
ISCCR |
25.0
kA |
Total discharge current (10/350 µs) |
ITotal(10/350) |
22.50
kA |
Lightning impulse current (10/350
µs) |
Iimp |
7.50
kA |
Nominal discharge current (8/20 µs) |
In |
20.00
kA |
Test voltage |
Uoc |
10.0
kV |
Total discharge current (8/20 µs) |
ITotal(8/20) |
100.00
kA |
Maximum discharge current (8/20 µs) |
Imax |
60.00
kA |
Voltage protection level |
Up |
1.50
kV |
Response time |
ta |
100
ns |
TOV 5 s L-N |
335
V |
|
TOV characteristic (TOV 5 s) |
withstand |
|
TOV 120 min L-N |
440
V |
|
TOV characteristic (120 min) |
withstand |
|
Cross-section of connected
conductors solid (min) |
1.00
mm2 |
|
Cross-section of connected
conductors solid (max) |
35.00
mm2 |
|
Cross-section of connected
conductors stranded (min) |
1.00
mm2 |
|
Cross-section of connected
conductors stranded (max) |
25.00
mm2 |
|
Fault indication |
red
indication field |
|
Degree of protection |
IP
20 |
|
Range of ambient temperatures
(min/max) |
-40
/ 80 °C |
|
Humidity |
5
- 95 % |
|
According to standard |
EN
61643-11:2012, IEC 61643-11:2011 |
|
ETIM Class |
EC000381 |
|
Plug module |
FLP-ZP-7,5-VBH/0 |
|
Customs tariff number |
85363090 |
|
EAN |
8595090566212 |
Dimensions:
Combination of lightning , TN-C, 7,5 kA (10/350 µs).
Related Product
Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)
Spark gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 3+1 mode.Installa..
Lightning current arrester between N and PE , TT system, 50 kA (10/350 µs)
park gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 1+1 mode.Installat..
Lightning current and surge arrester ,TT, 50 kA (10/350 µs), 100 kA (8/20 µs)
Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of v..
Lightning current and surge arrester , TT, 50 kA (10/350 µs), 100 kA (8/20 µs)
Pluggable module, visual fault signalling, module locking.Combination of varistor lightning current ..