• Surge arrester,TN and TT systems, up to 385 V AC, 40 kA (8/20 µs)

Pluggable module, visual fault signalling.

  • Varistor surge arrester.
  • Installation to LV installations, especially to sub-distribution boards.
  • For protection of the installations and equipments against impact of induced overvoltages during a lightning strike or switching overvoltages.


Specifications:


Parameter name

Parameter value

Type of SPD

T2

Mounting

DIN rail 35 mm

Maximum operating voltage

Uc

385.00 V AC

Maximum operating voltage

Uc

500.00 V DC

Type of network

TN

Maximum overcurrent protection

160 A gL/gG

Short-circuit current rating

ISCCR

50.0 kA

Nominal discharge current (8/20 µs)

In

20.00 kA

Maximum discharge current (8/20 µs)

Imax

40.00 kA

Voltage protection level

Up

1.80 kV

Voltage protection level at 5 kA

Up

1.30 kV

Response time

ta

25 ns

TOV 120 min L-N

440 V

TOV characteristic (120 min)

withstand

Cross-section of connected conductors solid (min)

1.00 mm2

Cross-section of connected conductors solid (max)

35.00 mm2

Cross-section of connected conductors stranded (min)

1.00 mm2

Cross-section of connected conductors stranded (max)

25.00 mm2

Fault indication

red indication field

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000941

Plug module

SLP-385 V/0

Customs tariff number

85363030

EAN

8595090519553




Dimensions:




Replacement module: SLP-385 V/0








Write a review

Note: HTML is not translated!
Captcha

Surge arrester,TN and TT systems, up to 385 V AC, 40 kA (8/20 µs)

0 reviews / Write a review

* Required fields



Related Product

Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)

Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)

Spark gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 3+1 mode.Installa..

Lightning current arrester between N and PE , TT system, 50 kA (10/350 µs)

Lightning current arrester between N and PE , TT system, 50 kA (10/350 µs)

park gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 1+1 mode.Installat..

Lightning current and surge arrester ,TT, 50 kA (10/350 µs), 100 kA (8/20 µs)

Lightning current and surge arrester ,TT, 50 kA (10/350 µs), 100 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of v..

Lightning current and surge arrester , TT, 50 kA (10/350 µs), 100 kA (8/20 µs)

Lightning current and surge arrester , TT, 50 kA (10/350 µs), 100 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking.Combination of varistor lightning current ..