• Module of surge ,6 A, installation C Low

Fault signalling by supply interruption.

  • Surge protection especially for LED lights.
  • Installation close to protected equipment in LV power circuits.
  • Also for equipment in external part of building with low exposure level (according to IEEE C62.41.2).


Specifications:

Parameter name

Parameter value

Type of SPD

T3

Mounting

installation box

Nominal voltage

Un

230 V AC

Maximum operating voltage

Uc

320.00 V AC

Nominal load current

IL

5.000 A

Maximum overcurrent protection

B 16 A

Short-circuit current rating

ISCCR

1.5 kA

Nominal discharge current (8/20 µs) L-N

In

3.00 kA

Nominal discharge current (8/20 µs) L+N-PE

In

5.00 kA

Nominal discharge current (8/20 µs) N-PE

In

3.00 kA

Test voltage L-N

Uoc

6.0 kV

Test voltage L+N-PE

Uoc

10.0 kV

Test voltage L-PE

Uoc

6.0 kV

Test voltage N-PE

Uoc

6.0 kV

Voltage protection level mode L-N

Up

1.50 kV

Voltage protection level mode L-PE

Up

1.50 kV

Voltage protection level mode N-PE

Up

1.50 kV

Response time L-N

ta

25 ns

Response time N-PE

ta

100 ns

Fault indication

loss of voltage

Remote indication

potential open contact

Maximum current of signalling

1.00 A

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 80 °C

Humidity

5 - 95 %

According to standard

EN 61643-11:2012, IEC 61643-11:2011

ETIM Class

EC000942

Customs tariff number

85363010

EAN

8595090567400


Dimensions:




Datasheet:

     DA-320-LED

Write a review

Note: HTML is not translated!
Captcha

Module of surge ,6 A, installation C Low

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..