Fine protection for max. 24 ports of Ethernet Cat. 5. Only a shielded version is supplied. Installation at the boundary of LPZ 2 and LPZ 3 zones, directly in front of the device.
Technical specifications
Type of SPD | C2,C3 | |
Location of SPD | ST 3 | |
Maximum operating voltage | Uc | 6V DC and 8V DC |
Nominal load current | IL | 0,100A |
C2 nominal discharge current (8/20 µs) per core | In | 0,20kA |
C2 total discharge current (8/20 µs) cores-PE | ITotal | 1,60kA |
C2 voltage protection level mode core-core at In | Up | 40V |
C2 voltage protection level mode core-PE at In | Up | 350V |
C3 voltage protection level mode core-core at 1 kV/µs | Up | 65V |
C3 voltage protection level mode core-PE at 1 kV/µs | Up | 350V |
Response time core-core | ta | 1ns |
Response time core-core | ta | 100ns |
Insertion attenuation at 250 MHz | 1,20dB | |
Connection (input - output) | RJ 45/RJ 45 | |
Degree of protection | IP 20 | |
Range of operating temperatures - min | -40 °C | |
Range of operating temperatures - max | 60 °C | |
According to standard | EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012 | |
ETIM Class | EC000943 |
DL-Cat. 5e 16 RACK PANEL
Related Product
Manual shears for allumium and copper cables
Specificationø mm<-->kg4280 mm0,55..
Adapters and Cables
Adapters and Cables used to complete your PDU installation. Cables and AdaptersDescriptionPart ..
AED 55.00
Knürr Elicon® Keyboard Drawer
idth: 675 /610 mmThe keyboard drawer creates space on your desktopLeg space is guaranteed in both th..
Side Panel 42U D800 For RMV Cabinet RAL9005 (Set Of 2)
Cabinet Side Panel For RMV 42U W600mm x D800mm RAL9005Complete cabinet includes:Part NoDes..
AED 535.00