•  DP-060-V/1-F16

Protection of power supply with output from the midle and non-grounded pole, also for powwer suply with

one pole grounded. Installation as close as possible to the protected equipment.

Technical specifications

Type of SPD

 

T3, C2

Connection (input - output) 

 

terminals-terminals

Location of SPD 

 

ST 2

Nominal voltage

Un

60V AC

Maximum operating voltage 

Uc

75V AC and 75V DC

Nominal load current 

IL

16,000A

C2 nominal discharge current (8/20 µs) per core 

In

2,00kA

C2 voltage protection level mode core-core at In

Up

390V

C2 voltage protection level mode core-PE at In 

Up

750,00V

Test voltage L+ - L- 

 

4,0kV

Test voltage L+(L-)-PE 

 

4,0kV

Test voltage M-PE 

 

4,0kV

voltage protection level L+ - L- 

 

0,39 kV

voltage protection level L+(L-)-PE

 

0,75 kV

voltage protection level M-PE 

 

0,75 kV

Maximum overcurrent protection 

 

16 A gL/gG or B 16 A

Response time L+ - L-

 

25ns

Response time L+(L-)-PE 

 

100ns

Response time M-PE 

 

100ns

Cross-section of connected conductors solid (min) 

 

0,14mm2

 

Cross-section of connected conductors solid (max) 

 

4,00 mm2

Cross-section of connected conductors stranded (min) 

 

0,14 mm2

Cross-section of connected conductors stranded (max)

 

2,50 mm2

Fault indication

 

red indicator

Degree of protection 

 

IP 20

Range of operating temperatures - min

 

-40 °C

Range of operating temperatures - max 

 

-70 °C

Mounting 

 

DIN rail 35 mm


Write a review

Note: HTML is not translated!
Captcha

DP-060-V/1-F16

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Surge protection for 2-core signalling networks, terminal block with screw terminals, 48 V DC, max. 0.5 A

Surge protection for 2-core signalling networks, terminal block with screw terminals, 48 V DC, max. 0.5 A

Coupling impedance (resistance), screw terminals.Coarse and fine surge protection for 2-core signa..

230V Power Circuit Board Assembly Kit For Heat Exchangers.

230V Power Circuit Board Assembly Kit For Heat Exchangers.

Spare parts for VERTIV/KNURR ACUR Cooling Unit and HEX Heat Exchangers..

Perforated rear panel 90° / 90° trapezoid (D- 1200,H-450).

Perforated rear panel 90° / 90° trapezoid (D- 1200,H-450).

Specification:Perforated rear panels fit W630 and W1230 Basic Frames, 45°, 90° and 90° Trapezoid Co..

Server Room Environmental Monitor Unit With Email Alerts.

Server Room Environmental Monitor Unit With Email Alerts.

VT325 is used for environment monitoring (room temperature, humidity, leakage, voltage, vibrati..