• CLSA-HF6

Combination of coarse and fine protection designed to protect data lines with high speed rates

Technical specifications

Type of SPD

 

C3,C2

Connection (input - output) 

 

LSA disconnection rail

Accessories 

 

grounding rail

Location of SPD 

 

ST 2+3

Maximum operating voltage 

Un

6V AC

Maximum operating voltage 

Uc

9V AC

Nominal load current 

IL

0,500A

C2 nominal discharge current (8/20 µs) per core `

In

500kA

C2 total discharge current (8/20 µs) cores-PE 

ITotal

10,00kA

C2 voltage protection level mode core-PE at In

Up

350V

C2 voltage protection level mode core-core at In 

Up

32V

C3 voltage protection level mode core-core at 1 kV/µs 

Up

15V

C3 voltage protection level mode core-PE at 1 kV/µs 

Up

350V

Response time core-core 

ta

1ns

Response time core-PE 

ta

100ns

Serial resistance per core 

R

1,60Ω

Treshold frequency core-core 

f

55,00MHz

Degree of protection 

 

IP 20

Range of operating temperatures - min

 

-40 °C

Range of operating temperatures - max 

 

70 °C

Mounting 

 

LSA disconnection rail

According to standard

 

EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012

ETIM Class 

 

EC001625


Write a review

Note: HTML is not translated!
Captcha

CLSA-HF6

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Curved Control Room Desk with Built In IT Equipment Cabinet.

Curved Control Room Desk with Built In IT Equipment Cabinet.

KVM-ready Technology Cabinet :- Up to 3x6 RU for integrating technology, typical for KVM application..

Surge protection for 2-core floating signalling networks, screwless terminal block, 48 V DC, max. 0.5 A

Surge protection for 2-core floating signalling networks, screwless terminal block, 48 V DC, max. 0.5 A

Coupling impedance (resistance), screwless terminals.Coarse and fine surge protection for 2-core sig..

Castor High Load Single

Castor High Load Single

Castors and FeetThe Conteg free-standing racks are always delivered in a standard configuration with..

AED100.00

Premium Technical Ergonomic Desk Side Framing Panels - 750mm High

Premium Technical Ergonomic Desk Side Framing Panels - 750mm High

Specifications: Modesty panel For Knürr Dacobas® desks with and without 19” pedesta..