Surge Protection Devices

Surge Protection Devices


Lightning current arrester for two 2-core signalling lines, max. 70 V.

Lightning current arrester for two 2-core signalling lines, max. 70 V.

Pluggable moduleLightning current arrester of two 2-core signalling lines.Installation at the bounda..

Model: BD-090-T-V/2-16
Lightning current arrester replacement module for 2/3-core ling lines, 60 V DC, max. 2 A

Lightning current arrester replacement module for 2/3-core ling lines, 60 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-060-V/1-FR2
Lightning current arrester replacement module for 2/3-core signalling lines, 12 V DC, max. 2 A

Lightning current arrester replacement module for 2/3-core signalling lines, 12 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-012-V/1-FR2
Lightning current arrester replacement module for 2/3-core signalling lines, 24 V DC, max. 2 A

Lightning current arrester replacement module for 2/3-core signalling lines, 24 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-024-V/1-FR2
Lightning current arrester replacement module for 2/3-core signalling lines, 6 V DC, max. 2 A

Lightning current arrester replacement module for 2/3-core signalling lines, 6 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-006-V/1-FR2
Lightning current arrester replacement module for two 2-core signalling lines, 12 V DC, max. 1 A

Lightning current arrester replacement module for two 2-core signalling lines, 12 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-012-V/2-FR1
Lightning current arrester replacement module for two 2-core signalling lines, 60 V DC, max. 1 A

Lightning current arrester replacement module for two 2-core signalling lines, 60 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-060-V/2-FR1
Lightning current arrester replacement module,for two 2-core signalling lines, 230 V DC, max. 0,5 A

Lightning current arrester replacement module,for two 2-core signalling lines, 230 V DC, max. 0,5 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-230-V/2-FR
Lightning current arrester, replacement module for 2/3-core signalling lines, 60 V DC, max. 1 A

Lightning current arrester, replacement module for 2/3-core signalling lines, 60 V DC, max. 1 A

gable module, coupling impedance (R – resistance), line separated from protective earth via GDT.Lig..

Model: BDM-060-V/1-FR1
Magazine 97 For 5pr Screw Terminal

Magazine 97 For 5pr Screw Terminal

The magazine 97 for 5 pair is the surge protection appliance for terminaldistribution boxes in Screw..

Model: 770.785.00094

AED 32.57

Spare Module For All SLP-275 Line - 8595090523680

Spare Module For All SLP-275 Line - 8595090523680

Technical specificationclass ETIM : EC000941..

Model: SLP-075 V / 0
Surge Arrester Varistor SPD Type O.V Max 350 VDC

Surge Arrester Varistor SPD Type O.V Max 350 VDC

Replaceable varistor module, visual fault signaling.varistor surge arrester, designed to be installe..

Model: SLP-275 V/1
SX-090 F75 F/F

SX-090 F75 F/F

BNC or F connectorsFine protection for coaxial inputs of TV systems. Suitable as the 2nd level of su..

Model: SX-090 F75 F/F
TNS Protection - 8595090517221

TNS Protection - 8595090517221

SPD type 2 – surge arrester 4-pole arrester for 3-phase TNS networks 4-pole varistor surge protectio..

Model: SLP-275 V/4
ZX-3, N50 F/M

ZX-3, N50 F/M

ZX-3, N50 F/MN50 connectors, quarter-wave short circuit.Protection of coaxial lines and telecommunic..

Model: 8595090519904
Showing 46 to 60 of 60 (4 Pages)