• Lightning current arrester for coaxial lines (antennas), 70 V DC

N connectors, 50 Ohm.

  • Lightning current arrester for coaxial line.
  • Installation at the boundary of LPZ 0 and LPZ 1 zones at the line entry into building.
  • For protection of telecommunication equipment against impact of direct or indirect lightning strike.
  • Suitable for the combined signal and power supply distribution.


Specifications:

ameter name

Parameter value

Type of SPD

D1,C2

Location of SPD

ST 1+2

Maximum operating voltage

Uc

70.00 V DC

Nominal load current

IL

6.000 A

Frequency range

f

0,00 - 3800,00 MHz

Impedance

Z

50 Ω

Power (CW)

P

40.00 W

Insertion loss typ. (max.)

A

0,2 (0,4) dB

VSWR typ. (max.)

VSWR

1,1 (1,2)

D1 impulse discharge current (10/350 µs) core-PE

Iimp

2.50 kA

C2 nominal discharge current (8/20 µs) core-PE

In

10.00 kA

Dynamic spark-over voltage at 1kV/µs

Udyn

700.00 V

Response time core-PE

ta

100 ns

Connection (input - output)

N 50

Degree of protection

IP 66

Range of ambient temperatures (min/max)

-40 / 80 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001466

Customs tariff number

85363030

EAN

8595090533467


Dimensions:





Datasheet:

     HX-090 N50 F/M

Write a review

Note: HTML is not translated!
Captcha

Lightning current arrester for coaxial lines (antennas), 70 V DC

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Heavy Duty 400V Surge Protected Office Power Outlet Strip

Specifications: Combi ON-OFF switch with integrated signal light Optimal user protection ..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.

Replacement module for FLP-PV700 V/U.Specifications:Parameter name Parameter valu..