Lightning current arrester for 2-core  signaling lines, replacement module, 24 V DC, max. 2 A

Lightning current arrester for 2-core signaling lines, replacement module, 24 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..

Model: BDG-024-V/1-FR2
Lightning current arrester for 2-core shielding floating signaling lines, replacement module, 48 V DC, max. 2 A

Lightning current arrester for 2-core shielding floating signaling lines, replacement module, 48 V DC, max. 2 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT...

Model: BDG-048-V/1-FR2
Lightning current arrester for 2/3-core signalling lines, 12 V DC, max. 1 A

Lightning current arrester for 2/3-core signalling lines, 12 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..

Model: BDM-012-V/1-FR1
Lightning current arrester for 2/3-core signalling lines, 230 V DC, max. 0.5 A

Lightning current arrester for 2/3-core signalling lines, 230 V DC, max. 0.5 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT..

Model: BDM-230-V/1-FR
Lightning current arrester for 2/3-core signalling lines, 24 V DC, max. 1 A

Lightning current arrester for 2/3-core signalling lines, 24 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..

Model: BDM-024-V/1-FR1
Lightning current arrester for 2/3-core signalling lines, 48 V DC, max. 1 A

Lightning current arrester for 2/3-core signalling lines, 48 V DC, max. 1 A

Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GD..

Model: BDM-048-V/1-FR1
Lightning current arrester for 3-phase TN-C system, 75 kA (10/350 µs)

Lightning current arrester for 3-phase TN-C system, 75 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking.Three-pole high performance lightning curr..

Model: FLP-25-T1-V/3
Lightning current arrester for 3-phase TN-C system, 75 kA (10/350 µs)

Lightning current arrester for 3-phase TN-C system, 75 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Three-pole high..

Model: FLP-25-T1-VS/3
Lightning current arrester for 3-phase TN-S system, 100 kA (10/350 µs)

Lightning current arrester for 3-phase TN-S system, 100 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Four-pole high ..

Model: FLP-25-T1-VS/4
Lightning current arrester for 3-phase TN-S system, 100 kA (10/350 µs)

Lightning current arrester for 3-phase TN-S system, 100 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking.Four-pole high performance lightning cur..

Model: FLP-25-T1-V/4
Lightning current arrester for 3-phase TT system, 100 kA (10/350 µs)

Lightning current arrester for 3-phase TT system, 100 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking.Combination of three-pole high performan..

Model: FLP-25-T1-V/3+1
Lightning current arrester for 3-phase TT system, 100 kA (10/350 µs)

Lightning current arrester for 3-phase TT system, 100 kA (10/350 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of ..

Model: FLP-25-T1-VS/3+1
Lightning current arrester for coaxial line, 360 V DC

Lightning current arrester for coaxial line, 360 V DC

Connectors N 50 Ohm.Lightning current arrester for coaxial line.Installation at the boundary of LPZ ..

Model: HX-470-N50-F/F
Lightning current arrester for coaxial line, 440 MHz band.

Lightning current arrester for coaxial line, 440 MHz band.

Connectors N 50 ohm, lambda/4 wave lenght shortcut.Lightning current arrester uses lambda/4 wave l..

Model: ZX-0,44-N50-F/F
Lightning current arrester for coaxial lines (antennas), 180 V DC

Lightning current arrester for coaxial lines (antennas), 180 V DC

N connectors, 50 Ohm.Lightning current arrester for coaxial line.Installation at the boundary of LPZ..

Model: HX-230 N50 F/F