• Combination of surge protections for signal and supply lines, 24 V DC, pluggable module, floating

Pluggable module, coupling impedance (R – resistance) in part of data, line separated from protective earth via GDT

  • Combination of two-stage surge protection of 2-core signalling line in data part and surge protection for ELV in supply part
  • Installation close to protected equipment
  • For protection of interfaces of I&C, electronic security and fire detection systems, etc., mainly for measuring circuits and sensors where signal and supply are transmited in one cable, against surge voltage


Specifications:

Parameter name

Parameter value

Cross-section of connected conductors solid (min)

0.14 mm2

Cross-section of connected conductors solid (max)

4.00 mm2

Cross-section of connected conductors stranded (min)

0.14 mm2

Cross-section of connected conductors stranded (max)

2.50 mm2

Fault indication

red indicator

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 70 °C

Humidity

5 - 95 %

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001473

Plug module

DMP-024-V/1-0

Nominal voltage

Un

24 V AC

Maximum operating voltage

Uc

25.00 V AC

Maximum operating voltage

Uc

36.00 V DC

Nominal load current

IL

16.000 A

Maximum overcurrent protection

16 A gL/gG nebo B 16 A

C2 nominal discharge current (8/20 µs) core-core

In

2.00 kA

Test voltage L+ - L-

4.0 kV

Test voltage L+(L-)-PE

4.0 kV

Test voltage M-PE

4.0 kV

voltage protection level L+ - L-

0.13 kV

voltage protection level L+(L-)-PE

0.95 kV

voltage protection level M-PE

0.75 kV

C2 voltage protection level mode M-PE at In

750.00 V

C2 voltage protection level mode core-PE at In

Up

950 V

C2 voltage protection level mode core-core at In

Up

230 V

Response time L+ - L-

25 ns

Response time L+(L-)-PE

100 ns

Response time M-PE

100 ns

Nominal voltage

Un

24 V DC

Maximum operating voltage

Uc

25.00 V AC

Maximum operating voltage

Uc

36.00 V DC

Nominal load current

IL

1.000 A

Treshold frequency core-core

f

4.00 MHz

Serial resistance per core

R

0.80 Ω

C2 nominal discharge current (8/20 µs) GND-PE

10.00 kA

C2 nominal discharge current (8/20 µs) per core

In

10.00 kA

C2 total discharge current (8/20 µs) cores-PE

ITotal

20.00 kA

C3 nominal discharge current (10/1000 µs) GND-PE

10.00 A

C3 nominal discharge current (10/1000 µs) core-PE

10.00 A

C3 nominal discharge current (10/1000 µs) core-core

In

10 A

C3 voltage protection level mode GND-PE at 1 kV/µs

550.00 V

C3 voltage protection level mode core-GND at 1 kV/µs

46.00 V

C3 voltage protection level mode core-core at 1 kV/µs

Up

46 V

Response time core-core

ta

1 ns

Response time core-GND

1 ns

Response time GND-PE

100 ns

Customs tariff number

85363010

EAN

8595090557999


Dimensions:




Replacement module: DMP-024-V/1-0






Write a review

Note: HTML is not translated!
Captcha

Combination of surge protections for signal and supply lines, 24 V DC, pluggable module, floating

0 reviews / Write a review

* Required fields



Related Product

Three-phase surge protection, TN and TT, 63 A

Three-phase surge protection, TN and TT, 63 A

Pluggable module, visual fault signalling, module locking, remote fault signalling.Combination of va..

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking, remote fault signalling.Four-pole varis..

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Surge arrester for three-phase system TN-S, 160 kA (8/20 µs)

Pluggable module, visual fault signalling, module locking.Fur-pole varistor surge arrester.Install..

Varistor surge arrester, TN and IT systems, 690 V AC, 120 kA (8/20)

Varistor surge arrester, TN and IT systems, 690 V AC, 120 kA (8/20)

Pluggable module, visual fault signalling, module locking.Three-pole varistor surge arrester.Insta..