• Surge protection for low-frequency 2-core signalling networks, 24 V DC, max. 0.1 A

Coupling impedance (inductance), screw terminals.

  • Coarse and fine surge protection for low-frequency 2-core signalling networks.
  • Installation close to protected equipment.
  • For protection of analogue measuring lines in the areas with RF disturbance.
  • Coarse and fine surge protection in differential mode (core – core) and common mode (core – PE).


Specifications:


Parameter name

Parameter value

Type of SPD

C2

Location of SPD

ST 2

Mounting

DIN rail 35 mm

Nominal voltage

Un

24 V DC

Maximum operating voltage

Uc

31.00 V DC

Nominal load current

IL

0.100 A

Treshold frequency core-core

f

0.07 MHz

D1 impulse discharge current (10/350 µs) per core

Iimp

0.50 kA

D1 total discharge current (10/350 µs) cores-PE

ITotal

1.00 kA

C2 nominal discharge current (8/20 µs) per core

In

5.00 kA

C2 total discharge current (8/20 µs) cores-PE

ITotal

10.00 kA

C2 voltage protection level mode core-PE at In

Up

80 V

C2 voltage protection level mode core-core at In

Up

65 V

C3 voltage protection level mode core-PE at 1 kV/µs

Up

55 V

C3 voltage protection level mode core-core at 1 kV/µs

Up

55 V

Response time core-core

ta

25 ns

Response time core-PE

ta

25 ns

Connection (input - output)

terminals-terminals

Cross-section of connected conductors solid (min)

0.14 mm2

Cross-section of connected conductors solid (max)

4.00 mm2

Cross-section of connected conductors stranded (min)

0.14 mm2

Cross-section of connected conductors stranded (max)

2.50 mm2

Degree of protection

IP 20

Range of ambient temperatures (min/max)

-40 / 70 °C

According to standard

EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012

ETIM Class

EC001625

Customs tariff number

85363010

EAN

8595090553335


Dimensions:




Write a review

Note: HTML is not translated!
Captcha

Surge protection for low-frequency 2-core signalling networks, 24 V DC, max. 0.1 A

0 reviews / Write a review

* Required fields



Related Product

Universal disconnection rail LSA

Universal disconnection rail LSA

Universal disconnection rail LSA 2/10. Universal disconnection rail LSA 2/10.Specifications:Param..

Mounting frame – 1 position for CLSA

Mounting frame – 1 position for CLSA

Mounting frame – 1 position. Mounting frame – 1 position for CLSA.Specifications: ..

Empty module cover

Empty module cover

SPD - for data, signalling and telecommunications lines / ICT / Ethernet and PoE - for 19" RACKprote..

Comb grounding rail for CLSA.

Comb grounding rail for CLSA.

Comb grounding rail for CLSA.Specifications: Parameter name Para..