RJ45 + SV
connectors.
- Two-stage
surge protection device for Ethernet protection, combined with PoE protection
including the injector.
- Installed
at the entry point into the building object, near the equipment to be
protected, at the interface of the LPZ 0 and LPZ 1 and higher zones.
- For use in Ethernet Cat. 6 lines with PoE (Power over Ethernet), operating in A and B modes, to protect them from peak overvoltages.
Specifications:
| Parameter name | Parameter
   value | |
| Type of SPD | D1,C2,C3 | |
| Location of SPD | ST
  1+2+3 | |
| Mounting | DIN
  rail 35 mm | |
| Maximum operating voltage | Uc | 8.50
  V DC | 
| Maximum operating voltage POE | Uc | 58.00
  V DC | 
| Nominal load current per core at 25
  °C | IL | 0.5
  A | 
| Treshold frequency core-core | f | 250.00
  MHz | 
| Insertion attenuation at treshhold
  frequency | 1.20
  dB | |
| D1 total discharge current (10/350
  µs) cores-PE | ITotal | 2.00
  kA | 
| C2 nominal discharge current (8/20
  µs) per core | In | 0.15
  kA | 
| C2 total discharge current (8/20 µs)
  cores-PE | ITotal | 10.00
  kA | 
| C2 voltage protection level mode
  (POE) at In = 1,25 kA | Uc | 90.00
  V | 
| C2 voltage protection level mode
  core-PE at In = 1,25 kA | Up | 700.00
  V | 
| C2 voltage protection level mode
  core-core at In | Up | 70
  V | 
| C3 voltage protection level mode
  (POE) at 1 kV/µs | 80.00
  V | |
| C3 voltage protection level mode
  core-PE at 1 kV/µs | Up | 500
  V | 
| C3 voltage protection level mode
  core-core at 1 kV/µs | Up | 80
  V | 
| Response time core-core | ta | 1
  ns | 
| Response time core-PE | ta | 100
  ns | 
| Connection (input - output) | RJ
  45/RJ 45 | |
| Degree of protection | IP
  20 | |
| Range of ambient temperatures
  (min/max) | -40
  / 80 °C | |
| Humidity | 5
  - 95 % | |
| According to standard | EN
  61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012 | |
| Customs tariff number | 85363030 | |
| EAN | 8595090566205 | 
Dimensions:
SPD for Ethernet 1 Gbite/s (Cat.6) with PoE, 2 kA (10/350 µs)
Related Product
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications: Parameter name ..
Replacement module for SLP-PV500 V/U.