Pluggable module, visual fault signalling, remote fault signalling.
- Varistor surge arrester.
- Installation to LV installations, especially to sub-distribution boards.
- For protection of the installations and equipments against impact of induced overvoltages during a lightning strike or switching overvoltages.
Specifications:
| Parameter name | Parameter
   value | |
| Type of SPD | T2 | |
| Mounting | DIN
  rail 35 mm | |
| Maximum operating voltage | Uc | 385.00
  V AC | 
| Maximum operating voltage | Uc | 500.00
  V DC | 
| Type of network | TN | |
| Maximum overcurrent protection | 160
  A gL/gG | |
| Short-circuit current rating | ISCCR | 50.0
  kA | 
| Nominal discharge current (8/20 µs) | In | 20.00
  kA | 
| Maximum discharge current (8/20 µs) | Imax | 40.00
  kA | 
| Voltage protection level | Up | 1.80
  kV | 
| Voltage protection level at 5 kA | Up | 1.30
  kV | 
| Response time | ta | 25
  ns | 
| TOV 120 min L-N | 440
  V | |
| TOV characteristic (120 min) | withstand | |
| Cross-section of connected
  conductors solid (min) | 1.00
  mm2 | |
| Cross-section of connected
  conductors solid (max) | 35.00
  mm2 | |
| Cross-section of connected
  conductors stranded (min) | 1.00
  mm2 | |
| Cross-section of connected
  conductors stranded (max) | 25.00
  mm2 | |
| Cross-section of remote indication
  conductors solid (max) | 1.5
  mm2 | |
| Cross-section of remote indication
  conductors stranded (max) | 1.5
  mm2 | |
| Fault indication | red
  indication field | |
| Remote indication | potential-free
  change-over contact | |
| Remote indication contacts | 250V/0,5A
  AC,250V/0,1A DC | |
| Degree of protection | IP
  20 | |
| Range of ambient temperatures
  (min/max) | -40
  / 80 °C | |
| Humidity | 5
  - 95 % | |
| According to standard | EN
  61643-11:2012, IEC 61643-11:2011 | |
| ETIM Class | EC000941 | |
| Plug module | SLP-385
  V/0 | |
| Customs tariff number | 85363030 | |
| EAN | 8595090527718 | 
Dimensions:
Replacement module: SLP-385 V/0
Surge arrester ,TN and TT systems, up to 385 V AC, 40 kA (8/20 µs)
Related Product
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications: Parameter name ..
Replacement module for SLP-PV500 V/U.
Replacement module for SLP-PV1000 V/Y (S).Specifications: Parameter name ..