Pluggable module, visual fault signalling, module locking, remote fault signalling.
- Combination of varistor SPD and encapsulated spark gap, connected in the 1+1 mode.
- Installation to LV installations, close to protected equipment.
- For protection of the equipments against impact of induced overvoltages during a lightning strike or switching overvoltages.
Specifications:
| Parameter name | Parameter value | |
| Type
  of SPD | T3 | |
| Mounting | DIN rail 35 mm | |
| Nominal
  voltage | Un | 230 V AC | 
| Maximum
  operating voltage L-N | Uc | 275.00 V AC | 
| Maximum
  operating voltage N-PE | Uc | 255.00 V AC | 
| Type
  of network | TT | |
| Maximum
  overcurrent protection | 63 A gL/gG | |
| Short-circuit
  current rating | ISCCR | 25.0 kA | 
| Nominal
  discharge current (8/20 µs) L-N | In | 5.00 kA | 
| Nominal
  discharge current (8/20 µs) N-PE | In | 10.00 kA | 
| Test
  voltage L-N | Uoc | 10.0 kV | 
| Test
  voltage N-PE | Uoc | 20.0 kV | 
| Voltage
  protection level mode L-N | Up | 1.00 kV | 
| Voltage
  protection level mode L-PE | Up | 1.50 kV | 
| Voltage
  protection level mode N-PE | Up | 1.50 kV | 
| Response
  time L-N | ta | 25 ns | 
| Response
  time N-PE | ta | 100 ns | 
| TOV
  5 s L-N | 335 V | |
| TOV
  characteristic (TOV 5 s) | withstand | |
| TOV
  120 min L-N | 440 V | |
| TOV
  characteristic (120 min) | safe failure | |
| TOV
  200 ms L-PE | 1 455 V | |
| TOV
  200 ms N-PE | 1 200 V | |
| TOV
  characteristic (TOV 200 ms) | safe failure | |
| Cross-section
  of connected conductors solid (min) | 1.00 mm2 | |
| Cross-section
  of connected conductors solid (max) | 35.00 mm2 | |
| Cross-section
  of connected conductors stranded (min) | 1.00 mm2 | |
| Cross-section
  of connected conductors stranded (max) | 25.00 mm2 | |
| Cross-section
  of remote indication conductors solid (max) | 1.5 mm2 | |
| Cross-section
  of remote indication conductors stranded (max) | 1.5 mm2 | |
| Fault
  indication L-N | red indication field | |
| Fault
  indication N-PE | no | |
| Remote
  indication | potential-free change-over contact | |
| Remote
  indication contacts | 250V/0,5A AC,250V/0,1A DC | |
| Degree
  of protection | IP 20 | |
| Range
  of ambient temperatures (min/max) | -40 / 80 °C | |
| Humidity | 5 - 95 % | |
| According
  to standard | EN 61643-11:2012, IEC 61643-11:2011 | |
| ETIM
  Class | EC000942 | |
| Customs
  tariff number | 85363030 | |
| EAN | 8595090519751 | 
Dimensions:
Single-phase surge protection , TN and TT systems, 63 A
Related Product
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 50 V DC.
Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..
Replacement module for FLP-PV700 V/U.
Replacement module for FLP-PV700 V/U.Specifications: Parameter name ..
Replacement module for SLP-PV500 V/U.
Replacement module for SLP-PV1000 V/Y (S).Specifications: Parameter name ..