- Easy
to use, rugged & versatile
- 31
calibration λ, 1% accuracy ISO/IEC 17025 traceable
- Improved
high power accuracy
- Autotest
with up to 3 λ displayed
- Long
battery life & micro USB external power
- Large
back-lit LCD, sunlight readable
- Interchangeable
connectors
- Large
memory with text naming & time stamp
- KITS™
reporting software with data security
- One
button memory dump to USB key
- MultiFiber
ID tone detection
- Full
QA & linearity test report
Specifications:
|
Attribute Name |
Attribute Value |
|
Detector
type |
Ge (5 mm) |
|
Calibration
accuracy |
1% (0.06
dB) |
|
Response
wavelength |
600 ~ 1650
nm |
|
Calibration
wavelengths |
660, 780,
820, 850, 880, 910, 940, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390,
1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650
nm |
|
Power range |
+15 ~ -30
dBm (for 660 ~ 820 nm, 1590 ~ 1650 nm) / +15 ~ -40 dBm (for 850 ~ 1570 nm) |
|
Mid-range
linearity |
0.06 dB
(typical) |
|
Total
uncertainty |
0.5 dB
(max) |
|
Wavelength
sensitivity (± 30 nm) |
0.03 dB
(typical) |
|
Response
uniformity across detector |
2 % (0.09
dB) |
|
ID tone
detection & Autotest sensitivity |
-37 dBm |
|
Calibration
validity |
3 years
(ISO/IEC 17025) |
|
Resolution |
0.01 dB |
|
Polarization
sensitivity |
< 0.05
dB (typical) |
|
Tone
detection |
150 ~ 9999
Hz ± 1 % |
|
Power |
2x AA (LR6)
Alkaline / External via USB |
|
Battery
life |
Up to 1000
hours |
|
Auto-off |
Selectable |
|
USB
interfaces |
USB-micro
for power & software / USB-A for memory key |
|
Software |
KITS (free
download) |
|
Memory |
1000 (4-λ
tests) / Unlimited on USB memory key |
|
Size |
124 x 81 x
25 mm |
|
Unit weight |
150 gm |
|
Shipping
weight |
1.1 kg |
|
Operating /
storage temperatures |
-15 to 55
°C / -25 to 70 °C |
|
Relative
humidity |
0 ~ 95 % |
|
Warranty |
3 years |
Large Area MPO Optical Power Meter, T2600XL-GE5
Related Product
FO Clean Clicker 2.50 SC, ST, FC, E2000 750 Cleans.
- With just one click the 2.5mm CleanClicker™ from Sticklers™ gets connectors clean.Features:7..
Top Cover
with cable entryTop cover compatible with Knürr Dacobas® 19” cabinet, depth 870 mmStandard accessory..
Mon Unit W/ CAN,Ether Prt,SD,USB,4Anlg,4Dig,2 12V -W/UK Plu.
The VT335 / IT Room Monitoring Unit can be used for remote environmental monitoring in sm..
Module Euro RJ11