• GPON/PON Power Meter, T6102AA-APC

An economical, in-line PON meter used during FTTH / PON service turn-up or maintenance, to perform a live optical power test with optical loss test (OLT) equipment.

  • Easy to use, compact, rugged & economical true PON / GPON tester
  • Fast reading and settling time
  • Sunlight-readable backlit display
  • Pass/fail display and LEDs
  • 1310 nm upstream, 1490/1550 nm downstream
  • 18 hr from AA alkaline batteries & auto off
  • 100 test memory & real-time clock
  • PC software for downloading results & setting pass/fail
  • 1-year warranty, 3-year calibration cycle
  • Full QA report with ISO9001-compliant calibration

Key Features:

  • Metal-free connectors: to avoid metal dust fragments damaging your tester and fiber-ends, we use high-end metal-free connectors.
  • Runs on Alkaline Batteries
  • Genuine 3-year calibration validity: genuine 3-year optical power meter re-calibration validity.

Specifications:

Attribute Name

Attribute Value

Detector type

InGaAs

Passband

Upstream: 1310 nm (FWHM: 1260 ~ 1360), Downstream: 1490 nm (FWHM: 1470 ~ 1505) & 1550 nm (FWHM: 1535 ~ 1570)

Power range

-40 ~ +10 dBm (@ 1310 nm) / -45~ +10 dBm (@ 1490 nm) / -45 ~ +23 dBm (@ 1550 nm)

Damage level (dBm)

+10 dBm (@ 1310 nm) / +10 dBm (@ 1490 nm) / +23 dBm (@ 1550 nm)

Isolation between wavelengths

> 40 dB

Uncertainty

0.5 dB (max)

Linearity

0.1 dB

Polarization loss

< 0.25 dB

Insertion Loss

< 1.5 dB

Return loss

50 dB

Display size

44 mm x 57 mm

Show results

dBm / W / dB, pass / fail

Display resolution

0.01 dB

Memory

99 records of 3-wavelength test

Data software

via mini-USB

Battery

4x AA (LR6) Alkaline

Battery life

18 hours

Auto off

Selectable

Instrument case

1.2 m drop tested

Operating / storage temperature

-10 ~ +60 °C / -25 ~ +70 °C

Relative humidity

95 %

Unit size

200 mm x 90 mm x 43 mm

Unit weight

0.4 kg

Shipment weight

1 kg

Calibration cycle (recommended)

3 years

Warranty

1 year

 

Write a review

Note: HTML is not translated!
Captcha

GPON/PON Power Meter, T6102AA-APC

0 reviews / Write a review

* Required fields



Related Product

FO Patch Cord 9/125 Spx OS2 2.0mm LC/UPC-LC/UPC-3m LSOH

FO Patch Cord 9/125 Spx OS2 2.0mm LC/UPC-LC/UPC-3m LSOH

Fiber patch cord for interconnect application is designed for use in data communication, process con..

Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)

Lightning current arrester between N and PE , TT system,100 kA (10/350 µs)

Spark gap for N-PE, pluggable module, module locking.For connection Type 1 SPD in 3+1 mode.Installa..

Module with surge protection for additional installation, remote fault signalling.

Module with surge protection for additional installation, remote fault signalling.

Remote fault signalling.SPD for additional installation to devices or equipments.Installation to LV ..

Surge arrester ,TN and TT systems,440 V AC, 40 kA (8/20 µs)

Surge arrester ,TN and TT systems,440 V AC, 40 kA (8/20 µs)

Pluggable module, visual fault signalling, remote fault signalling.Varistor surge arrester.Install..