An economical, in-line PON meter used during 10G FTTH / PON
service turn-up or maintenance, to perform a live test with the OLT equipment.
- Easy
to use, compact, rugged & economical true PON meter
- Fast
reading and settling time
- Sunlight-readable
backlit display
- Pass
/ fail display
- 1270
& 1310 nm upstream, 1490 & 1577 nm downstream
- 10
hr from built-in Lithium battery & auto-off
- 100
test memory & real-time clock
- PC
software for downloading results & setting pass / fail
- 1-year
warranty, 3-year calibration cycle
- Full
QA report with ISO9001 compliant calibration
Key Features:
- Metal-free
connectors: to avoid metal dust fragments damaging your tester and
fiber-ends, we use high-end metal-free connectors.
- Genuine
3-year Calibration Validity: genuine 3 year optical power meter
recalibration validity.
Specifications:
Attribute Name |
Attribute Value |
Detector
type |
InGaAs |
Passband |
Upstream:
1270 nm (FWHM: 1260~1280) & 1310 nm
(FWHM: 1290~1330), Downstream: 1490
nm (FWHM: 1470~1505) & 1577 nm
(FWHM: 1570 ~1585) |
Power range |
-30 ~ 10 dBm (@ 1270 &
1310 nm) / -45 ~ 10 dBm (@ 1490 &
1577 nm) |
Damage
level |
> 10 dBm |
Isolation
between wavelengths |
Up to 40 dB |
Uncertainty |
0.5 dB
(max) |
Linearity |
0.1 dB |
Polarization
loss |
< 0.25
dB |
Insertion
Loss |
< 1.5 dB |
Return loss |
50 dB |
Display
size |
44 mm x 57
mm |
Show
results |
dBm / W /
dB, pass / fail |
Display
resolution |
0.01 dB |
Memory |
99 records
of 4 wavelengths test |
Data
software |
via
mini-USB |
Battery |
7.4V
1000mAH rechargeable Lithium |
Battery
life |
10 hours |
Auto off |
Selectable |
Power
adaptor/charger |
Input:
100~240V, 50/60Hz 0.3 A; Output: 8.4V, 0.5A; Connector: 1.3(ID) x 3.5(OD) x
9.5 (L) mm, ID=positive, OD=negative |
Instrument
case |
1.2 m drop
tested |
Operating /
storage temperature |
10 ~ 50 °C
/ -25 ~ 70 °C |
Relative
humidity |
95% |
Unit size |
200 mm x 90
mm x 43 mm |
Unit weight |
0.4 kg |
Shipment
weight |
1 kg |
Calibration
cycle (recommended) |
3 years |
Warranty |