• Dual Laser Optical Test Source, T2822

This dual optical laser source is a general purpose test source for single mode systems, at 1310-1550 nm. Typical applications include fiber optic attenuation measurement, polarity testing and fiber identification on critical system

  • Easy to use, rugged & versatile
  • Long battery life, micro USB power/charger
  • Interchangeable connectors with dust cap & tilt bail
  • Superior re-connection repeatability, < 0.1 dB
  • Excellent stability
  • Autotest & Multi-Fiber ID Tone generator
  • Full QA & test reports ISO/IEC 17025 traceable

Specifications:

Attribute Name

Attribute Value

Output wavelength

Port 1: 1310, 1550 nm Laser

Output power

0 dBm ±1 dB (@ 9/125 µm)

Adjust output power

Adjustable over 7 dB in 0.01 dB steps

Short term stability (for 15 min, typical ±2 °C, after warm up, ORL < -25 dB)

0.04 dB

Stability over temperature

0.6 dB (typical)

Wavelength initial tolerance (@ 25 °C)

20 nm

Spectrum width (FWHM)

3 nm (typical)

Wavelength drift

0.4 nm /°C (typical)

Reconnection repeatability (95% confidence)

0.1 dB

Calibration validity (ISO/IEC 17025)

3 years

Modulated output

270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones

Autotest (not available for 470, 540 nm LED sources)

Compatible with KI Autotest power meter port & matching λ

Power

Battery / External power via USB

Battery types

2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via USB)

Battery life

Laser/LED source: 90/80 hours in Autotest, typical

Auto off

Selectable

Case

Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested

Size

190 mm x 105 mm x 35 mm

Unit weight

0.42 kg

Shipping weight

1.5 Kg

Operating / storage temperature

-15 to 55 °C / -25 to 70 °C

Relative humidity

0 ~ 95 %

Warranty

3 years

 

Write a review

Note: HTML is not translated!
Captcha

Dual Laser Optical Test Source, T2822

0 reviews / Write a review

* Required fields



Related Product

Cabinet Top Cover Miracel W600 D600

Cabinet Top Cover Miracel W600 D600

or use in conjunction with the CoolBlast® fan topClosed top cover with cable entry for protection ag..

Surge protection with RFI filter,10 A.

Surge protection with RFI filter,10 A.

Fault signalling due to power supply interruption, visual fault signalling.Surge protection with int..

VOLTANYL • ø 4 mm

VOLTANYL • ø 4 mm

Nylon fishtape ø 4 mm with interchangeable terminals M4, complete of flexible starting spinner withe..

Dual Laser Optical Test Source, T2822

Dual Laser Optical Test Source, T2822

This dual optical laser source is a general purpose test source for single mode systems, at 1310-15..