A simple fiber testing kit, excellent for low to modest test
volume on single mode systems. An optical power meter with laser source kit.
Typical Test Applications
- Optical
power at 8 calibrated λ, -60 to +5 dBm range.
- Optical
loss on SM fiber at 1310/1550 nm, 60 dB range.
- Reporting
software for cable loss, manual data entry.
- Optical
continuity / tone source & meter, 12 fiber Multi-Fiber ID, 40 dB
range.
- Generally
meets safety regulations & standards
based test procedures.
Connector & battery summary
SC interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AAA alkaline. Run time >300 hours.
Source 2 x AAA alkaline. Run time >40 hours.
Includes:
- FIBER
OPTIC LASER TEST SOURCE T9822A
- POCKET
FIBER OPTIC POWER METER T9600A
- CANVAS
CARRYING POUCH
Specifications:
Attribute Name |
Attribute Value |
POCKET
FIBER OPTIC POWER METER T9600A |
|
Detector
type |
InGaAs |
Response
wavelength |
600 ~ 1700
nm |
Calibration
wavelengths |
850, 1300,
1310, 1390, 1490, 1550, 1610, 1625 nm |
Power range |
+5 ~ -60
dBm |
Mid-range
linearity |
0.04 dB
(typical) |
Total
uncertainty |
0.3 dB
(max) |
Wavelength
sensitivity (± 30 nm) |
0.03 dB
(typical) |
ID tone
detection sensitivity |
up -50 dBm |
Simple Test Kit SM TK056
Related Product
Cable Coaxial BT-3002 ITA 3.6mm - 100m
PVC jacket to be used mo-stly inside conduits.PVC Ø 3,6 ± 0,15 mm.Double layer screening tape, (foil..
FO Patch Cord 9/125 Dpx OS2 2.0mm SC/UPC-SC/UPC-5m LSOH
Fiber patch cord for interconnect application is designed for use in data communication, process con..
VOLTATWIST • ø 5,8 mm - Accessories and spare parts
Galvanised steel cage, vertical version for VOLTATWIST rodsSpecificationPart NumberØ rodL mmkg ..
2,5 mm2 4 slots cross-connector
SPD - for data, signalling and telecommunications lines / I&C / Accesories for I&CCross conn..