An economical, in-line PON meter used during FTTH / PON service
turn-up or maintenance, to perform a live optical power test with optical loss
test (OLT) equipment.
- Easy
to use, compact, rugged & economical true PON / GPON tester
- Fast
reading and settling time
- Sunlight-readable
backlit display
- Pass/fail
display and LEDs
- 1310
nm upstream, 1490/1550 nm downstream
- 18
hr from AA alkaline batteries & auto off
- 100
test memory & real-time clock
- PC
software for downloading results & setting pass/fail
- 1-year
warranty, 3-year calibration cycle
- Full
QA report with ISO9001-compliant calibration
Key Features:
- Metal-free
connectors: to avoid metal dust fragments damaging your tester and
fiber-ends, we use high-end metal-free connectors.
- Runs
on Alkaline Batteries
- Genuine
3-year calibration validity: genuine 3-year optical power meter
re-calibration validity.
Specifications:
|
Attribute Name |
Attribute Value |
|
Detector
type |
InGaAs |
|
Passband |
Upstream:
1310 nm (FWHM: 1260 ~ 1360), Downstream: 1490 nm (FWHM: 1470 ~ 1505) &
1550 nm (FWHM: 1535 ~ 1570) |
|
Power range |
-40 ~ +10
dBm (@ 1310 nm) / -45~ +10 dBm (@ 1490 nm) / -45 ~ +23 dBm (@ 1550 nm) |
|
Damage
level (dBm) |
+10 dBm (@
1310 nm) / +10 dBm (@ 1490 nm) / +23 dBm (@ 1550 nm) |
|
Isolation
between wavelengths |
> 40 dB |
|
Uncertainty |
0.5 dB
(max) |
|
Linearity |
0.1 dB |
|
Polarization
loss |
< 0.25
dB |
|
Insertion
Loss |
< 1.5 dB |
|
Return loss |
50 dB |
|
Display
size |
44 mm x 57
mm |
|
Show
results |
dBm / W /
dB, pass / fail |
|
Display
resolution |
0.01 dB |
|
Memory |
99 records
of 3-wavelength test |
|
Data
software |
via
mini-USB |
|
Battery |
4x AA (LR6)
Alkaline |
|
Battery
life |
18 hours |
|
Auto off |
Selectable |
|
Instrument
case |
1.2 m drop
tested |
|
Operating /
storage temperature |
-10 ~ +60
°C / -25 ~ +70 °C |
|
Relative
humidity |
95 % |
|
Unit size |
200 mm x 90
mm x 43 mm |
|
Unit weight |
0.4 kg |
|
Shipment
weight |
1 kg |
|
Calibration
cycle (recommended) |
3 years |
|
Warranty |
1 year |
GPON/PON Power Meter, T6102AA-APC
Related Product
2,5 mm2 4 slots cross-connector
SPD - for data, signalling and telecommunications lines / I&C / Accesories for I&CCross conn..
Isolation spark gap for Ex areas, 100 kA (10/350 µs), 100 V DC.
Connecting cable and M8 bolt with nut, stainless steel enclosure.Heavy duty encapsulated isolating s..
Caution Static Sensitive Area Aisle Marking Tape, 3" X 54' Ideal For ESD-Safe Area Designation
Product Features Scuff-resistant vinyl plastic Tough, durable floor tape Easy to adhe..
Knürr DI-STRIP® Safety Standard (D Schuko– 5, L - 532).
Specification:Standard safety models consist of a combined overvoltage protection/mains filter ele..