• Advanced Test Kit SM MM, TK076

A fiber testing kit with an optical power meter and light source, effective for low to medium test volume on single mode & multimode systems.

Typical testing applications

  • Optical power at 25 calibrated wavelengths, -60 to +15 dBm range.
  • Optical loss on SM fiber 1310 / 1550 nm, 60 dB range.
  • Optical loss on MM fiber 850 / 1300 nm, 40 dB (@ 62.5um) range, EF compliant.
  • Loss testing automation & reporting with AutoTest and KITS™ software.
  • Optical continuity / tone checking, 12 fiber Multi-Fiber ID, 50 dB range.
  • Generally meets safety regulations & standards based test procedures.

Connector & battery summary

SC interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AA alkaline. Run time >1000 hours. Micro USB pwr /charging.
Source 2 x AA alkaline. Run time >80 hours. Micro USB pwr /charging.

Includes:

  • LED & LASER QUAD OPTICAL TEST SOURCE T2824
  • HANDHELD OPTICAL POWER METER T2600
  • PADDED CANVAS CARRY POUCH OPT149

Specifications:

Attribute Name

Attribute Value

HANDHELD OPTICAL POWER METER T2600

Detector type

InGaAs

Calibration accuracy

1% (0.06 dB)

Response wavelength

600 ~ 1700 nm

Calibration wavelengths

780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm

Power range

+10 ~ -60 dBm (for 780 ~ 980 nm) / +10 ~ -70 dBm (for 1270 ~ 1650 nm)

Mid-range linearity

0.04 dB (typical)

Total uncertainty

0.3 dB (max)

Wavelength sensitivity (± 30 nm)

0.03 dB (typical)

ID tone detection & Autotest sensitivity

Up to -50 dBm

 

Write a review

Note: HTML is not translated!
Captcha

Advanced Test Kit SM MM, TK076

0 reviews / Write a review

* Required fields



Related Product

Cable Manager 36U Metal Vertical Left/Right – Black.

Cable Manager 36U Metal Vertical Left/Right – Black.

36U Metal Cable Management panel set left/right.Features:Height:  1598  mmEquipment mounti..

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Isolation spark gap, 50 kA (10/350 µs), screws, withstand voltage 100 V DC.

Two M8 bolts with nuts.Encapsulated high-performance isolating spark gap.For indirect connection (ea..

Steel Duct brush with wire kernal

Steel Duct brush with wire kernal

Specificationø:<-->kg125mm330mm2,5..

C20 IEC LOCK + Dual Locking Connector

C20 IEC LOCK + Dual Locking Connector

As an innovative solution for Data Centres, PDUs & servers, the C20 IEC Dual locking Connector ..