• Outdoor Armored Fiber Optic Cable 12 Core OS1 9/125 Network Cable.
  1. Optical  fibre: Singlemode (FOTAG color code)
  2.  Tube : PBT Polyester
  3.  Waterproofing : Gel
  4.  Reinforcement :Water blocking aramid and glass yarns
  5.  Inner sheath : Indoor/outdoor LSOH, blue
  6.  Armour : Corrugated steel armour               
  7.  Outer jacket : HD polyethylene, black.

Main Cable Characteristics

Standards

                                                                   From 4 to 12 fibres cables

Temperature Range

Transport and Storage

-40 / +70 °C

Installation

-5 / +50°C

Operating

-40 / +70°C

Max. Pulling Force (N)

1200

Crush Resistance (N/cm)

900

Min. Bending radius (mm)

150

Standard Packaging

1000 or 2100 m drums

Nominal sheath thickness (mm)

1

Nominal diameter (mm)

10.5

Nominal weight (kg/km)

125

Marking of outer jacket

Manufacturing year – ACOME – fibre count and type – product reference + metric 

Cables and optical fibersStandards

  •  IEC/EN 60793
  •  IEC/EN 60794-1

Cabling Systems

  •  EN 50173
  •  ISO 11801

Applications

  • IEEE 802.3 10|M and 10Gbit
  • IEEE 802.5 Token ring
  • ANSI X3T9-5 (FDDI)
  • ATM (155, 622)

Write a review

Note: HTML is not translated!
Captcha

Outdoor Armored Fiber Optic Cable 12 Core OS1 9/125 Network Cable.

  • AED5.25

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F

Voltage limiting device, VLD of class 2.2, type VLD-O+F, limiting of occurrence non-permissible touc..

SPD for high-speed Ethernet networks, LPZ 0 and higher

SPD for high-speed Ethernet networks, LPZ 0 and higher

LPZ 0 and higher, for high-speed Ethernet networks with PoECombination of coarse and fine protection..

DIN Rail Power Supply 12VDC.

DIN Rail Power Supply 12VDC.

- DIN rail Power supply 230VAC/ 12VDC, 0.63A...

Knürr DI-STRIP® Classic (CH Type 13).

Knürr DI-STRIP® Classic (CH Type 13).

Specification:Optionally with illuminated switch; 2-pole switching. Socket rotation: 45° .Feed ca..