Fine protection for max. 24 ports of Ethernet Cat. 5. Only a shielded version is supplied. Installation at the
boundary of LPZ 2 and LPZ 3 zones, directly in front of the device.
Technical specifications
Type of SPD | C2,C3 | |
Location of SPD | ST 3 | |
Maximum operating voltage | Uc | 6V DC and 8V DC |
Nominal load current | IL | 0,100A |
C2 nominal discharge current (8/20 µs) per core | In | 0,20kA |
C2 total discharge current (8/20 µs) cores-PE | ITotal | 1,60kA |
C2 voltage protection level mode core-core at In | Up | 40V |
C2 voltage protection level mode core-PE at In | Up | 350V |
C3 voltage protection level mode core-core at 1 kV/µs | Up | 65V |
C3 voltage protection level mode core-PE at 1 kV/µs | Up | 350V |
Response time core-core | ta | 1ns |
Response time core-core | ta | 100ns |
Insertion attenuation at 250 MHz | 1,50dB | |
Connection (input - output) | RJ 45/RJ 45 | |
Degree of protection | IP 20 | |
Range of operating temperatures - min | -40 °C | |
Range of operating temperatures - max | 60 °C | |
According to standard | EN 61643-21+A1,A2:2013, EN IEC 61643-21+A1,A2:2012 | |
ETIM Class | EC000943 |
Shielded 8-Channel RJ45 Network Lightning Arrester Panel
- Brand: SALTEK - Czech Republic Categories Surge Protection Devices
- Product Code: DL-Cat. 5e 8 RACK PANEL
- MPN: 8595090529309
Terms & Conditions
- Product Information: Specifications, images and availability are subject to change without notice.
- Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
- Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
- Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.
Related Product
800mm 41U IT Equipment Rack Clear Glass Front Door Panel
MaterialSheet steel 1.0 mm, single safety glass panel 4.0 mm, clear glass, double door 6.0 mmFinish/..
Cat7 SFTP Network Cable 500m Roll LSOH For High-Speed Data.
HCS S/FTP Cat7 500mLong product name HCS S/FTP Cat7 500m:Category 7+ S/FTP 100 Ohm Horizontal LAN Ca..
AED3.49
Tube Mount System Type E, for top screen mounting column (150 mm).
Specification:Flat screen mount for flat screens with VESA bracket 75 and 100 mm. With integrated ..
Replacement module for BDM-012-V/2-J(F)Rx
SPD - for data, signalling and telecommunications lines / I&C / Spare modulesReplacement module ..