OPTICAL CABLE MINI BREAK-OUT - 2 to 24 SINGLEMODES FIBERS 9/125 - IEC 60794-1-E3
INDOOR/OUTDOOR
1. Optical fibers : Fibers insulated diameter 900µm (tight)
2. Strength members : Glass yarns
3. Rip cord : Blue halogen flame retardant compound
Outer Outer Ø = 6.6 mm
Sheath Thickness = 0.8 mm
Main Cable Characteristics
Temperature Range | Transport and Storage | -30 / +70 °C |
Installation | -5 / +50°C | |
Operating (1) | -10 / +60°C | |
Maximum pulling force (1) Fibre elongation ≤ 0.5 % ; Reversible delta Alpha | 500N | |
Crush Resistance (N/cm) (1) | 200 | |
Crush resistance without fibre break | 900 N/cm | |
Minimum static bending radius (1) | 10 x Ø | |
Minimum kink diameter | 10 x Ø | |
Fire resistance | Compliant | |
Nominal câble weight | 22 kg/km | |
Fiber Optic Network Cable 2 Core 9/125 G652D LSZH Low Smoke Cable.
- Brand: ACOME - France Categories In/Out
- Product Code: 030.135.00094
- MPN: N6600A
AED2.77
Terms & Conditions
- Product Information: Specifications, images and availability are subject to change without notice.
- Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
- Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
- Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.
Related Product
T-shaped connection bracket, BVL series
T shape terminal for BVL-50-xxx or BVL-100-xxx.Terminal for BVL series.Connection to cables etc.Easy..
ESD Safe Electronics Workstation Desk With 3-Drawer Right Pedestal(W1140,H750).
Specifications: Combi desk with 4 legs and link-up extrusion. Offset leg to ensure u..
Hydraulic tensioners-puller for overhead lines stringing
Hydraulic machine suitable to operate as a tensioner or as a puller to string or recover t..
Lightning current and surge arrester, 12.5 kA (10/350 µs), 60 kA (8/20 µs)
Pluggable module, visual fault signalling, remote fault signalling.Varistor lightning current arrest..