PVC jacket to be used mo-stly inside conduits.PVC Ø 3,6 ± 0,15 mm.
Double layer screening tape, (foil), highly effective against high frequency interferences. screening percentage 100% AL-POL.
Physical injection foamed polyethylene.Dielectric FPE Ø 1,9 ± 0,05 mm.
Electrical Data |
Nominal Impedance : 75 Ohm±3 |
Capacitance : 52 pF/m±2 |
Velocity ratio : 85 % Attenuation (at 20°C) |
MHz 5 | dB/100m 3,5 |
MHz 50 | dB/100m 9,8 |
MHz 200 | dB/100m 19,7 |
MHz 470 | dB/100m 31,0 |
MHz 800 | dB/100m 41,3 |
MHz 860 | dB/100m 42,9 |
MHz 1000 | dB/100m 46,6 |
MHz 1750 | dB/100m 64,5 |
MHz 2050 | dB/100m 69,7 |
MHz 2150 | dB/100m 71,3 |
MHz 2400 | dB/100m 75,4 |
MHz 3000 | dB/100m 84,3 |
Structural Return Loss
| >30 dB | ||
| >26 dB | ||
MHz 860-2150 | >20 dB |
Screening Efficiency
MHz 30 -1000 | >75 |
MHz 1000-2000 | >95dB |
MHz 2000-3000 | >90dB |
Transfer Impedance (return path) | <5 mOhm/m |
Inner conductor resistance | 556 Ohm/Km |
Outer conductor resistance | 80 Ohm/Km |
Tension test of the jacket (spark test) | 4 kV |
STANDARD PACKING type & metres (250m refills for Arianna unwinders) | AR250 |
Other packings | 250 and 500m drums |
Screw type “F” connector | C.TV.FM.3 |
BNC connector | C.BNC36.MC |