• Fire Rated Safety Cable 2 Core 2.5mm² for Emergency Wiring

Construction

Conductor

Solid bare copper (IEC / EN 228, BS 6360, VDE 0295, HD 383)

Insulation

Fire resistant silicon rubber (HD 22.1, BS 7655 EI 2), colors: BS7671/HD308-S2/VDE0293-308 (for more than 5 cores white core/black numbered)

Separator

Polyester tape

Drain Wire

0.80 mm Solid tinned copper

Screen

Tinned Copper Wire Braiding  (70% Coverage)  (EN 50288)

Shield

Aluminium laminated polyester tape

Sheath

HFFR, Red (RAL 3000) EN 50290-2, VDE 0207 HM2, BS 7655 LTS1 / LTS3

 

Technical and Electrical Properties (20°C)

 

Conductor Resistance(max)

1 mm² : 18  Ω/km  -  1.5 mm² : 12  Ω/km   -   2.5 mm² : 7.4 Ω/km

Insulation Resistance(min)

200 M.Ωxkm

Separator

Polyester tape

Operating Voltage

300 V / 500 V                   Test  Voltage  2000 V

Temperate Range

Fixed             -30 °C ...+90 °C             Flexing -5 °C ...+60 °C

Min. Bending Radius

Fixed                8 x Cable Diameter,    Flexing 15 x Cable Diameter

Flame Tests

IEC 60332-1, IEC 60332-3-24, (BS 4066 part 1&3), EN 50266-2-4

Insulation Integrity

IEC 60331, BS 6387 C , W, Z, EN 50200 PH30

Smoke Density

IEC 61034, BS 7622, HD 606

Corrosive Gas measurement

IEC 60754-2, BS 6425, EN 50267

Write a review

Note: HTML is not translated!
Captcha

Fire Rated Safety Cable 2 Core 2.5mm² for Emergency Wiring

  • AED4.49

* Required fields


Terms & Conditions
  • Product Information: Specifications, images and availability are subject to change without notice.
  • Enquiries & Pricing: All enquiries and displayed prices are subject to availability and confirmation by Dafnia.
  • Quotation & Payment: Final pricing, applicable taxes, delivery and payment terms will be stated in the quotation or invoice.
  • Order Confirmation: Orders are confirmed only upon written acceptance by Dafnia and receipt of the agreed payment or approved purchase order, where applicable.

Related Product

Cabinet 21U W600 D600 Smaract W/ Side Pnl, MPost - RAL7035

Cabinet 21U W600 D600 Smaract W/ Side Pnl, MPost - RAL7035

For components in acc. with IEC 297- 3Access from all sides, removable cover sFlexible assembly of t..

Superstructure Level System, ESD version (W1600,D500).

Superstructure Level System, ESD version (W1600,D500).

Specifications:ESD version for discharging electrostatic charges. Superstructure level designed as..

14 AWG Heavy-Duty RG11 Coax Cable for Long Distance TV - 305m

14 AWG Heavy-Duty RG11 Coax Cable for Long Distance TV - 305m

RG-11/U GAS INJECTED FOAM PE CATV COAXIAL CABLE WITH 60% ALUMINUM BRAID- SWEEP TO 3.0 GHZRATING: ETL..

AED874.75

Cable RG11,CCTV,14AWG, CU COND.,95% BC,BRAID Shield-305m/Rl.

Cable RG11,CCTV,14AWG, CU COND.,95% BC,BRAID Shield-305m/Rl.

Description:Conductors: 14 AWG (1/.064) Solid Bare Copper.Rating: CL2/UL-1581.Dielectric: Foam Polye..