A simple fiber cable test kit, the right solution for low to
modest test volume on multimode LAN, with some single mode capability.
Typical test applications
- Optical
power at 8 calibrated λ, -60 to +10 dBm range.
- Loss
on MM fiber 850 / 1300 nm, 40 dB range, EF compliant.
- Optical
loss on SM fiber at 1300 nm, 28 dB range.
- Reporting
software for cable loss (manual data entry).
- Optical
continuity / tone source & meter with 12 Multi-Fiber ID fiber, 40 dB
range.
- Generally
meets safety regulations & standards
based test procedures.
Connector & battery summary
SC interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AAA alkaline. Run time >300 hours.
Source 2 x AAA alkaline. Run time >35 hours.
Includes:
- FIBER
OPTIC LED TEST SOURCE T9812A
- POCKET
FIBER OPTIC POWER METER T9600A
- CANVAS
CARRYING POUCH
Specifications:
|
Attribute Name |
Attribute Value |
|
POCKET
FIBER OPTIC POWER METER T9600A |
|
|
Detector
type |
InGaAs |
|
Response
wavelength |
600 ~ 1700
nm |
|
Calibration
wavelengths |
850, 1300,
1310, 1390, 1490, 1550, 1610, 1625 nm |
|
Power range |
+5 ~ -60
dBm |
|
Mid-range
linearity |
0.04 dB
(typical) |
|
Total
uncertainty |
0.3 dB
(max) |
|
Wavelength
sensitivity (± 30 nm) |
0.03 dB
(typical) |
|
ID tone
detection sensitivity |
up -50 dBm |
Simple LAN Test Kit MM, TK052
Related Product
FO Splice Cassette 24 Port W/Lid – Black
Single Element Management High Density Splice Cassettes12 & 24 splice capacityProfessional cable..
Cable 2C, 22AWG,Unshielded, PVC R20004-1A -305m/Roll
2/C 22 AWG COMMERCIAL AUDIO AND GENERAL PURPOSE LOW VOLTAGEPOWER LIMITED CABLE 60C 300V RISER RATED&..
AED 402.16
Jensen Tools JTK-93LW Inch Electro-Mech. Service Kit in Roto-Rugged™ Wheeled Case
This kit offers a comprehensive selection of tools for electronic repair, plant maintenance and hard..