A simple fiber cable test kit, the right solution for low to
modest test volume on multimode LAN, with some single mode capability.
Typical test applications
- Optical
power at 8 calibrated λ, -60 to +10 dBm range.
- Loss
on MM fiber 850 / 1300 nm, 40 dB range, EF compliant.
- Optical
loss on SM fiber at 1300 nm, 28 dB range.
- Reporting
software for cable loss (manual data entry).
- Optical
continuity / tone source & meter with 12 Multi-Fiber ID fiber, 40 dB
range.
- Generally
meets safety regulations & standards
based test procedures.
Connector & battery summary
SC interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AAA alkaline. Run time >300 hours.
Source 2 x AAA alkaline. Run time >35 hours.
Includes:
- FIBER
OPTIC LED TEST SOURCE T9812A
- POCKET
FIBER OPTIC POWER METER T9600A
- CANVAS
CARRYING POUCH
Specifications:
|
Attribute Name |
Attribute Value |
|
POCKET
FIBER OPTIC POWER METER T9600A |
|
|
Detector
type |
InGaAs |
|
Response
wavelength |
600 ~ 1700
nm |
|
Calibration
wavelengths |
850, 1300,
1310, 1390, 1490, 1550, 1610, 1625 nm |
|
Power range |
+5 ~ -60
dBm |
|
Mid-range
linearity |
0.04 dB
(typical) |
|
Total
uncertainty |
0.3 dB
(max) |
|
Wavelength
sensitivity (± 30 nm) |
0.03 dB
(typical) |
|
ID tone
detection sensitivity |
up -50 dBm |
Simple LAN Test Kit MM, TK052
Related Product
Base Assembly With Cable Entry W800 D1000 Miracel
For covering the rack undersideWith rubber sealing for flexible cable entry on the front and rearPro..
Cirrus - Lamp®
Technical dataCompact fluorescent tube, 18 wattCoated parabolic grid in luminaire head prevents dire..
Cabinet 48U W600 D1100 F/Supervented R/Ver.Div Door -9005
The OPTIMAL ROF rack is designed to cope with the demanding needs of IT equipment within a data cent..