• Knürr Elicon® Working Level

ESD version

  • ESD version for discharging electrostatic charges
  • Working level designed as sliding section for convenient access to the horizontal cable duct
  • The working level can be mounted at any height between two side panels and can be varied in the height at any time
  • Worktop (30 mm) with ergonomically shaped front edge
  • Spacious horizontal cable duct, can be accessed via sliding worktop and folding mechanism
  • Cable duct with integrated C-rail for mounting installation components and mounting slot for general accessories

Material / Finish

  • Crosspiece: Extruded aluminium, antistatic, powder-coated texture
  • Support arm: sheet steel, antistatic powder-coated texture
  • Worktop: three layer particle board,FP / Y E1 version, fire protection class B2
  • Worktop cover: high pressure plastic laminate
  • Cable duct, horizontal: sheet steel, rolled, antistatic, powder-coated texture

Colours

  • Worktop: light-grey
  • Metal parts: RAL 7035 light-grey

Load rating

1500 N (static surface load)

Standards

  • DIN 68761 for worktop
  • EN 438 HGS class for high pressure plastic laminate
  • IEC 61340 electrostatics

Supply schedule

1 Worktop

1 Crosspiece

2 Desk stabilizers

1 Cable duct

1 Detailed mounting instructions

Mounting material

How supplied

Pre-assembled modules

Write a review

Note: HTML is not translated!
Captcha

Knürr Elicon® Working Level

0 reviews / Write a review

* Required fields



Related Product

Surge arrester ,TN and TT systems,440 V AC, 40 kA (8/20 µs)

Surge arrester ,TN and TT systems,440 V AC, 40 kA (8/20 µs)

Pluggable module, visual fault signalling, remote fault signalling.Varistor surge arrester.Install..

Surge protection for small-voltage AC/DC power supply networks with RFi filter, up to 48 V AC or DC

Surge protection for small-voltage AC/DC power supply networks with RFi filter, up to 48 V AC or DC

Visual fault singallingSurge protection with integrated RFi filter.Installation to LV installations,..

Surge protection for 2-core signalling lines, installation close to protected equipment, 24 V DC, max. 2 A

Surge protection for 2-core signalling lines, installation close to protected equipment, 24 V DC, max. 2 A

Coupling impedance (L2 – inductance).Coarse and fine surge protection for 2-core signalling lines.In..

Fan Assembly 2Way Exp 6Way With Thermo 110V MCL

Fan Assembly 2Way Exp 6Way With Thermo 110V MCL

For forced rack ventilation, (three-piece) Installtion in cover, no loss of installati- on spac..