AQ1000 Optical Time Domain Reflectometer
Specifically designed to increase the productivity of field personnel working on the installation and deployment of
optical access networks such as Fiber To The Home (FTTH).
- Wavelengths: 1310 / 1550 nm
- Dynamic ranges: 32 / 30 dB
Multi-touch touchscreen:
Tap, swipe, pinch or press. the high resolution, responsive 5.0-inch multi-touch capacitive touchscreen and hard-key
buttons make OTDR operations simple and intuitive.
One-button measurement:
Simply pressing one single button, the AQ1000 initiates an OTDR measurement, detects and comprehensively
characterizes network events with PASS/FAIL judgment based on user-defined thresholds. The measurement data
can be saved automatically if desired.
Long battery operation time:
No worrying about running out of battery power during your daily work. The AQ1000’s high capacity Li-Ion battery
will last for 10 hours under the Telcordia standard conditions
Built-in PC and LS, and VLS:
Power checker (PC) - Measures and displays optical power of incoming light for testing network performance.
Light source (LS) - Outputs a stable, continuous wave/modulated light for measuring end-to-end attenuation
accurately when paired with an optical power sensor.
Specifications
Items | Specifications |
Wavelength (nm)*4 | 1310 ±20/1550 ±20 |
Applicable fiber | SM (ITU-T G.652) |
Distance range (km) | 0.2, 0.5, 1, 2, 5, 10, 20, 30, 50, 100, 200, 256 |
Pulse width (ns) | 3, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000, 5000, 10000, 20000 |
Sampling resolution | min. 5 cm |
Number of sample points | max. 256000 |
Distance measurement | ±(1 m + Measurement distance × 2 × 10−5 |
accuracy (m) | ±1 sampling resolution) |
Event dead zone (m)*1 | ≤ 0.8 |
Attenuation dead zone (m)*2, *4 | 4/5 |
Dynamic range (dB)*3, *4 | 32/30 |
Loss measurement accuracy | ±0.03 dB/dB |
Reflection accuracy | ±2 dB |
Laser class | Class 1M |
*1: Pulse width = 3 ns, Return loss ≥ 55 dB, at a 1.5 dB or less point from an unsaturated peak level.
*2: Pulse width = 10 ns, Return loss ≥ 55 dB, at a point where the backscatter level is within ±0.5 dB of the normal level.
*3: Pulse width = 10000 ns, Measurement time = 3 minutes, Sampling resolution = 8 m, SNR = 1.
*4: typical
OTDR AQ1000 SM 1310/1550nm
Related Product
Light cable drum unreeling frame with galvanised steel reels
Specification<-->kg200500mm530-700 mm15..
Lightning current and surge arrester ,TN-C, 37.5 kA (10/350 µs), 180 kA (8/20 µs)
Pluggable module, visual fault signalling, module locking.Three-pole varistor lightning current ar..
Stackable cabinet with tambour doors 2 FH (D 430).
Specification:Completely bonded and doweled corpus made of melamin resin coated chipboards accordin..
Cable Pulling Grip With One Eye 30 - 40mm L1250mm
Cable pulling grips for subterranean cables in canals,tubes and other constructionsSpecificationCabl..
AED 305.00