• OTDR AQ1000 SM 1310/1550nm

AQ1000 Optical Time Domain Reflectometer

Specifically designed to increase the productivity of field personnel working on the installation and deployment of

optical access networks such as Fiber To The Home (FTTH).

  • Wavelengths: 1310 / 1550 nm
  • Dynamic ranges: 32 / 30 dB

 

Multi-touch touchscreen:

Tap, swipe, pinch or press. the high resolution, responsive 5.0-inch multi-touch capacitive touchscreen and hard-key

buttons make OTDR operations simple and intuitive.

 

One-button measurement:

Simply pressing one single button, the AQ1000 initiates an OTDR measurement, detects and comprehensively

characterizes network events with PASS/FAIL judgment based on user-defined thresholds. The measurement data

can be saved automatically if desired.

 

Long battery operation time:

No worrying about running out of battery power during your daily work. The AQ1000’s high capacity Li-Ion battery

will last for 10 hours under the Telcordia standard conditions

 

Built-in PC and LS, and VLS:

Power checker (PC) - Measures and displays optical power of incoming light for testing network performance.

Light source (LS) - Outputs a stable, continuous wave/modulated light for measuring end-to-end attenuation

accurately when paired with an optical power sensor. 


Specifications

Items

Specifications

Wavelength (nm)*4

1310 ±20/1550 ±20

  Applicable fiber

SM (ITU-T G.652)

Distance range (km)

0.2, 0.5, 1, 2, 5, 10, 20, 30, 50, 100, 200, 256

Pulse width (ns)

3, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000, 5000, 10000, 20000

Sampling resolution

min. 5 cm

Number of sample points

max. 256000

Distance measurement

±(1 m + Measurement distance × 2 × 10−5

accuracy (m)

±1 sampling resolution)

Event dead zone (m)*1

≤ 0.8

Attenuation dead zone (m)*2, *4

4/5

Dynamic range (dB)*3, *4

32/30

Loss measurement accuracy

±0.03 dB/dB

Reflection accuracy

±2 dB

Laser class

Class 1M

       *1: Pulse width = 3 ns, Return loss ≥ 55 dB, at a 1.5 dB or less point from an unsaturated peak level.  

       *2: Pulse width = 10 ns, Return loss ≥ 55 dB, at a point where the backscatter level is within ±0.5 dB of the normal level.   

       *3: Pulse width = 10000 ns, Measurement time = 3 minutes, Sampling resolution = 8 m, SNR = 1. 

       *4: typical

Write a review

Note: HTML is not translated!
Captcha

OTDR AQ1000 SM 1310/1550nm

0 reviews / Write a review

* Required fields



Related Product

Mini Distributor

Mini Distributor

For Knürr Elicon® Electronic WorkstationExtruded aluminum mini distributor, powdercoated, antistatic..

Plastic duct brush on teflon kernal

Plastic duct brush on teflon kernal

Specificationø:<-->kg44mm2000mm0,1..

Fiberglass Rod 6mm-100m Vertical - Yellow

Fiberglass Rod 6mm-100m Vertical - Yellow

Fiberglass Rod VOLTASIX ø 6 mm with Polypropylene outer coating comes spooled on a vertical galvaniz..

دإ Dhs1,902.00

Adjustable boom with aluminium cable roller

Adjustable boom with aluminium cable roller

Specificationø 210 - ø 110 ↔ 110 mm<-->kg50-80cm10..