AQ1000 Optical Time Domain Reflectometer
Specifically designed to increase the productivity of field personnel working on the installation and deployment of
optical access networks such as Fiber To The Home (FTTH).
- Wavelengths: 1310 / 1550 nm
- Dynamic ranges: 32 / 30 dB
Multi-touch touchscreen:
Tap, swipe, pinch or press. the high resolution, responsive 5.0-inch multi-touch capacitive touchscreen and hard-key
buttons make OTDR operations simple and intuitive.
One-button measurement:
Simply pressing one single button, the AQ1000 initiates an OTDR measurement, detects and comprehensively
characterizes network events with PASS/FAIL judgment based on user-defined thresholds. The measurement data
can be saved automatically if desired.
Long battery operation time:
No worrying about running out of battery power during your daily work. The AQ1000’s high capacity Li-Ion battery
will last for 10 hours under the Telcordia standard conditions
Built-in PC and LS, and VLS:
Power checker (PC) - Measures and displays optical power of incoming light for testing network performance.
Light source (LS) - Outputs a stable, continuous wave/modulated light for measuring end-to-end attenuation
accurately when paired with an optical power sensor.
Specifications
Items | Specifications |
Wavelength (nm)*4 | 1310 ±20/1550 ±20 |
Applicable fiber | SM (ITU-T G.652) |
Distance range (km) | 0.2, 0.5, 1, 2, 5, 10, 20, 30, 50, 100, 200, 256 |
Pulse width (ns) | 3, 10, 20, 30, 50, 100, 200, 300, 500, 1000, 2000, 5000, 10000, 20000 |
Sampling resolution | min. 5 cm |
Number of sample points | max. 256000 |
Distance measurement | ±(1 m + Measurement distance × 2 × 10−5 |
accuracy (m) | ±1 sampling resolution) |
Event dead zone (m)*1 | ≤ 0.8 |
Attenuation dead zone (m)*2, *4 | 4/5 |
Dynamic range (dB)*3, *4 | 32/30 |
Loss measurement accuracy | ±0.03 dB/dB |
Reflection accuracy | ±2 dB |
Laser class | Class 1M |
*1: Pulse width = 3 ns, Return loss ≥ 55 dB, at a 1.5 dB or less point from an unsaturated peak level.
*2: Pulse width = 10 ns, Return loss ≥ 55 dB, at a point where the backscatter level is within ±0.5 dB of the normal level.
*3: Pulse width = 10000 ns, Measurement time = 3 minutes, Sampling resolution = 8 m, SNR = 1.
*4: typical
OTDR AQ1000 SM 1310/1550nm
Related Product
19“ Drawer 1HU for Front Installation.
Specification:For installation in 19“ racks with vertical profiles in the front. For storage of se..
Cable Manager With Double Brush -410x215 Mm
Protection of Cable OpeningsEdging strips and brush panels help to protect cables on entry and ..
Lightning current arrester replacement module, for two 1-core signalling lines, 48 V DC, max. 1 A
Pluggable module, coupling impedance (R – resistance), line separated from protective earth via GDT...
Cable Control 2C 1sqmm LIY(ST)Y/18AWG SCN 305m/Rll
ApplicationsThese shielded and PVC insulated cables are used as signal transmission cables in indust..
AED 2.06